INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY
I
27
RO
TA 608 NA
TUR
AL GA
S
3 x 10 FUSE 1 PIECE REQUIRED
5 x 1,5 ANTIGRON CABLE REQUIRED (CABLE SIZE DEPENDS ON THE DISTANCE WHERE THE
OVEN IS TO BE INSTALLED)
OPERATES WITH 3 PHASE (380 V/50 Hz), DRAWS 7 A POWER PER PHASE
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.3 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN SHOULD BE ON THE FLOOR AND 1.5 m PROXIMITY OF THE OVEN
BURNER’S HEAT CAPACITY IS 60.000 kcall / 75 Kw. BURNER IN ACCORDANCE WITH
ITS CAPACITY SHOULD BE 30 cm HIGH ABOVE THE FLOOR WHERE THE OVEN IS TO BE
INSTALLED.
SHAFT OUTPUT SHALL BE 22 cm DIAMETER DOUBLE WALL 1 m PROXIMITY TO THE PLACE
WHERE THE OVEN IS TO BE INSTALLED
STEAM SHAFT OUTLET IS 13 cm, IT SHOULD BE 1 m PROXIMITY TO PLACE WHERE THE OVEN
IS TO BE INSTALLED
Shaft Installation Connection
Oven shaft should be made of spiral pipes or metal pipes. Steam aspirator shaft and fume extraction
shafts should not be jointed.
(Figure16)
Содержание Rota 507
Страница 1: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I1 ...
Страница 2: ...2 I memak com 2 I memak com ...
Страница 14: ...14 I memak com Figure2 Figure3 ...
Страница 21: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I21 Figure10 ...
Страница 28: ...28 I memak com Figure17 Figure18 ...
Страница 47: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I47 ...
Страница 48: ...48 I memak com ...