3 x 10 A FUSE 1 PIECE REQUIRED
5 x 1,5 ANTIGRON CABLE (CABLE SIZE DEPENDS ON THE DISTANCE WHERE THE OVEN IS TO
BE INSTALLED)
OPERATES WITH 3 PHASE (380 V/50 Hz), DRAWS 7 A POWER PER PHASE
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.5 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN NEED TO BE ON THE GROUND AND 1,5 m PROXIMITY TO THE OVEN.
BURNER’S HEAT CAPACITY IS 80.000 kcall / 95 Kw. BURNER IN ACCORDANCE WITH
ITS CAPACITY SHOULD BE 30 cm HIGH ABOVE THE FLOOR WHERE THE OVEN IS TO BE
INSTALLED.
SHAFT OUTPUT SHALL BE 22 cm DIAMETER DOUBLE WALL 1 m PROXIMITY TO THE PLACE
WHERE THE OVEN IS TO BE INSTALLED
STEAM SHAFT OUTLET IS 13 cm, IT SHOULD BE 1 m PROXIMITY TO PLACE WHERE THE OVEN
IS TO BE INSTALLED
RO
TA 609 ELE
CTRICAL
3 x 63 FUSE 1 PIECE REQUIRED
OPERATES WITH 3 PHASE (380 V/50 Hz), DRAWS 48 A POWER IN AVERAGE
5 x 16 ANTIGRON CABLE REQUIRED (CABLE SIZE DEPENDS ON THE DISTANCE WHERE THE
OVEN IS TO BE INSTALLED)
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.3 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN SHOULD BE ON THE FLOOR AND 1.5 m PROXIMITY OF THE OVEN
STEAM SHAFT OUTLET IS 13 cm, IT SHOULD BE 1 m PROXIMITY TO PLACE WHERE THE OVEN
IS TO BE INSTALLED
RO
TA 609 NA
TUR
AL GA
S
3 x 10 FUSE 1 PIECE REQUIRED
5 x 1,5 ANTIGRON CABLE REQUIRED (CABLE SIZE DEPENDS ON THE DISTANCE WHERE THE
OVEN IS TO BE INSTALLED)
OPERATES WITH 3 PHASE (380 V/50 Hz), DRAWS 7 A POWER PER PHASE
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.5 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN SHOULD BE ON THE FLOOR AND 1.5 m PROXIMITY OF THE OVEN
BURNER’S HEAT CAPACITY IS 60.000 kcall / 70 Kw. BURNER IN ACCORDANCE WITH
ITS CAPACITY SHOULD BE 30 cm HIGH ABOVE THE FLOOR WHERE THE OVEN IS TO BE
INSTALLED.
SHAFT OUTPUT SHALL BE 22 cm DIAMETER DOUBLE WALL 1 m PROXIMITY TO THE PLACE
WHERE THE OVEN IS TO BE INSTALLED
RO
TA 608 ELE
CTRICAL
3 x 63 FUSE 1 PIECE REQUIRED
OPERATES WITH 3 PHASE (380 V/50 Hz), DRAWS 48 A POWER IN AVERAGE
5 x 16 ANTIGRON CABLE REQUIRED (CABLE SIZE DEPENDS ON THE DISTANCE WHERE THE
OVEN IS TO BE INSTALLED)
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.3 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN SHOULD BE ON THE FLOOR AND 1.5 m PROXIMITY OF THE OVEN.
STEAM SHAFT OUTLET IS 13 cm, IT SHOULD BE 1 m PROXIMITY TO PLACE WHERE THE OVEN
IS TO BE INSTALLED
Содержание Rota 507
Страница 1: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I1 ...
Страница 2: ...2 I memak com 2 I memak com ...
Страница 14: ...14 I memak com Figure2 Figure3 ...
Страница 21: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I21 Figure10 ...
Страница 28: ...28 I memak com Figure17 Figure18 ...
Страница 47: ...INSTALLATION AND USER MANUAL FOR BAKERY OVEN WITH ROTATING TROLLEY I47 ...
Страница 48: ...48 I memak com ...