MEMAK MAKİNE shall not be held responsible for the problems those may rise for causing others
to install electricity installation other than our company’s staff and persons to be authorized by our
company.
Those required for Machine’s electrical connection;
RO
TA810 ELE
CTRICAL
3 x 80 A FUSE 1 PIECE REQUIRED
3x2,5 ANTIGRON CABLE (NEUTRAL, EARTH 1 x 6) (CABLE SIZE DEPENDS ON THE DISTANCE
WHERE THE OVEN IS TO BE INSTALLED)
OPERATES WITH 3 PHASE (380 V / 50 Hz), AVERAGE VOLTAGE DRAWN 65 A.
IT IS NECESSARY TO DRAW INSTALLATION WITH ½” PVC PIPE TO 2.3 m HEIGHT FROM
FLOOR WHERE THE OVEN IS TO BE INSTALLED FOR THE FRESH WATER ENTRY.
WASTE WATER DRAIN NEED TO BE ON THE GROUND AND 1,5 m PROXIMTY TO THE OVEN.
STEAM SHAFT OUTLET IS 13 cm, IT SHOULD BE 1 m PROXIMITY TO PLACE WHERE THE OVEN
IS TO BE INSTALLED