FOCKE MELER GLUING SOLUTIONS
3-8
INSTALLATION
2. Remove the six screws fastening the connection support plate and
power switch, on the left side of the equipment. Pass the signal cable
(Ø4-8 mm) through the bushing Pg9 and attach to the internal fitting,
ensuring that the cable reaches the control board connector at the
point where it is to be installed (CN4).
3. Remove the connector from the panel and connect the two cable wires
to their corresponding connector terminals:
1 contact NO
2 contact NO
4. Reconnect the connector to the panel.
5. Check that the cable is correctly connected and that its passage
through the electric cabinet presents no risk of jamming, being cut or
any other accidental damage.
Warning:
Connect to 24 V (AC or DC). If connected to 230 V the load current
cannot be less than 50 mA.
Note:
take into account the image of CN4 external standby connector, do not
confused with CN4 temperature ok .
Starting up the motor (ok ext)
1. If this is the only signal being connected, use 0.5 mm
2
two-wire cable.
Install an electrical wall bushing Pg9 next to the electrical supply input.
2. Thread the power cord (max. Ø4-8mm) through the electrical wall
bushing Pg9 and fasten it to the inside anchor, making sure that the cord
reaches the power card connector.
3. Connect the two wires from the start-up signal to the terminals XP1
and XP2. This is a double terminal, which makes it necessary to
connect each wire in one of the two holes in the terminal. Since this
contact is not under voltage, there is no connection polarity.
4. Make sure that the cables are firmly attached by the terminal screws.
5. For the signal to work, the led ‘ok ext’ on the control panel must be on.
1 2
Содержание B4 NON-STOP
Страница 1: ...MA 5081 E 030120 GLUING SOLUTIONS ADHESIVE MELTER B4 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 54: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 62: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 65: ...ELECTRICAL DRAWINGS 7 1 MA 5081 E B4 NS ADHESIVE MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PART LIST This page is intentionally left blank ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PART LIST This page is intentionally left blank ...