FOCKE MELER GLUING SOLUTIONS
4-16
MELTER OPERATION
5. Ext on LED:
when the equipment is operating in external start-stop
(OK) mode, and the external permission contact is closed, this LED will be
illuminated; if the external contact is open, this LED is turned off. This LED is
green in colour.
6. Ext ref LED:
when operating in external reference mode and the external
reference voltage is other than zero, this LED will be illuminated. When the external
reference voltage is zero, this LED will be turned off. This LED is green in colour.
7. In/Out LED:
when operating in external set point reference mode, these LEDs
will be activated and deactivated as the speed ramp options are programmed.
These LEDs are green in colour.
Modes of operation
First of all, we must bear in mind that when password security is enabled and
the control card is not manipulated during one minute, it is blocked and you
need to enter the password. To prevent this from happening, password security
may be disabled following the steps in the section ‘Password security’.
Mode of operation with internal pumping control and internal speed control
In this working mode the user has full control of the start/stop function and
speed pump set.
Follow the steps below to use this operating mode:
1. Press the ON/OFF button to light up the control card.
2. Select ‘ok’ in the position ‘int’ and ‘ref’ in the position ‘int’.
To activate the start-up status, all of the following conditions must be met:
• That the input for pumping permission (E4) at central control is activated, as
pumping is not possible unless the equipment temperature is OK.
• That pumping is enabled with the pumping ON-OFF button (red LED is
turned off).
• That the failure input is not activated (E5), in which case starting the
pump would be impossible. In case of the pump be operating and this
input is activated, pumping will cease immediately.
If a speed has been previously set, this value will be shown on the display
and the pump will start to rotate at the speed indicated provided that all prior
conditions are met. Otherwise:
3. Using the up/down arrows, select the rotation speed and/or wait for
pumping permission to be enabled (red LED is turned off).
At this moment, the pump will start to rotate at the speed indicated on the display.
4. Adjust the rotation speed to the value required for the application. The
selected value is set pressing the right arrow key after blinking three times.
Содержание B4 NON-STOP
Страница 1: ...MA 5081 E 030120 GLUING SOLUTIONS ADHESIVE MELTER B4 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 54: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 62: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 65: ...ELECTRICAL DRAWINGS 7 1 MA 5081 E B4 NS ADHESIVE MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PART LIST This page is intentionally left blank ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PART LIST This page is intentionally left blank ...