4-25
MELTER OPERATION
MA-5081-E
B4 NS ADHESIVE MELTER MANUAL
For safety reasons, this pressure must be discharged when the circuit exceeds
the working value -normally with the circuit closed and the pump activated-
which requires the use of a discharge or bypass valve.
This valve may be a manual adjustment valve, using a threaded allen head
screw, or with pneumatic control, using a pressure regulator and a pressure
gauge. In the latter case, the adhesive circuit pressure has a 1:13 ratio to the
pressure displayed on the pressure gauge.
Adjusting the manual valve
Follow the steps below to set the pressure using this type of valve
(approximate):
1. Screw the spindle in as far as possible in the clockwise direction. In
this position, the maximum pressure is 81,5 kg/cm
2
(80 bar).
2. Gradually loosen anti-clockwise until the desired pressure is reached.
Each millimetre the spindle sticks out corresponds -approximately- to
a reduction of 9 kg/cm
2
(8,82 bar).
By default, the equipment is calibrated with a hydraulic pressure of
approximately 40 bar.
Pneumatic valve control
To adjust the pressure with this valve model, follow these steps:
1. Unlock the pressure regulator control by pulling on it gently.
2. Turn it clockwise to increase the pressure. This will be seen reflected
on the pressure gauge located next to it.
Warning
: Do not exceed 6 bar of pressure. This corresponds to 80 bar on the
hydraulic circuit.
Turning off the melter
If it is necessary to disconnect the melter:
1. Press the control card ON/OFF button to switch off the card.
2. Disconnect the equipment’s power switch located on the side, next to
the power supply input.
3. Disconnect the applicators’ pneumatic power supply and the electric
supply to the control programmer if applicable.
Содержание B4 NON-STOP
Страница 1: ...MA 5081 E 030120 GLUING SOLUTIONS ADHESIVE MELTER B4 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 54: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 62: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 65: ...ELECTRICAL DRAWINGS 7 1 MA 5081 E B4 NS ADHESIVE MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PART LIST This page is intentionally left blank ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PART LIST This page is intentionally left blank ...