5. Screw the nut (1) back in place and place the filter inside the
distributor.
6. Replace the filter cap screw if damaged.
7. Screw the filter cap turning right and tighten as far as possible.
8. Continue to work as normal.
Warning:
Use the appropriate protective equipment for high temperatures.
Pump maintenance
Leakage inspection
The pump is equipped with a gasket system in the shaft and gaskets in
the seating pump to prevent adhesive leaks through it. Some adhesive can
sometimes leak out and therefore the gasket system in the shaft or the
gaskets in the seating pump must be changed. Before making any changes,
make sure the position of the leak.
Warning:
Change the gasket when the pump is hot.
Remove the shaft coupling from the pump. Remove the screws fastening the
gasket. Replace the gasket system in the shaft or the gaskets in the seating
pump and reassemble.
However, before making any changes and in case of doubt should check with
the Technical Assistance Service of Meler.
Warning:
Always wear protective gloves and safety glasses. Risk of burns.
Gear motor maintenance
Cleaning the motor fan
Regularly check the condition of the motor fan and its vent grid.
If dust has accumulated, blow gently with air to clean (remove the protective
cover if necessary).
Checking the lubricant
The gears are delivered filled with synthetic grease for lubrication -free from
external contamination- ‘
for life
’. Room temperature 0 ÷ 40°C with peaks of up
to -20°C and +50°C.
Содержание B4 NON-STOP
Страница 1: ...MA 5081 E 030120 GLUING SOLUTIONS ADHESIVE MELTER B4 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 54: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 62: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 65: ...ELECTRICAL DRAWINGS 7 1 MA 5081 E B4 NS ADHESIVE MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PART LIST This page is intentionally left blank ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PART LIST This page is intentionally left blank ...