Operation Manual for the EMT 10T, 10/4, and 10/4T
Melco Embroidery Systems
4-6
Lubrication
2. When
needle bar driver/v-rail
displays,
press
. This moves the needle
case to its first position for oiling (needle 1).
Refer to Figure 4-9 to lubricate the needle
bar driver at needle 1. Also refer to Figure 4-
9 to lubricate the v-rail. Put the oil in the v-
rail as close to the needle case as possible.
To access these areas on the EMT 10/4 or
10/4T, insert the oiler through the hole with
the red bushing on the front of the panel.
Use a flashlight if needed. Press
to
move the needle case to needle 10. Oil the
needle bar driver as shown in Figure 4-10.
Also, lubricate the v-rail on this side of the
head. Press
when done. The head will
move back and forth to distribute the oil.
Figure 4-9
Top view of needle case
Put 3-5 drops of oil
in this hole
Figure 4-10
Top view of needle case
Put 3-5 drops of
oil in this hole
▲
▲
▲
Put 1 drop of
oil in the v-rail
Put 1 drop of
oil in the v-rail