CLI NTP Parameter
The NTP configuration page is used to set up the additional NTP parameters
needed for a more specific configuration of the NTP subsystem.
The default configuration of the timeserver consists of a local clock, which represents
the hardware clock of your LANTIME system and the GPS reference clock. The local
clock is only chosen as the NTP time reference after the GPS clock lost its
synchronisation. The stratum level of this local clock is set to 12, this ensures that
clients recognise the switchover to the local clock and are able to eventually take
further actions. The local clock can be disabled.
Because the GPS reference clock is internally connected to the LANTIME system by
using a serial connection, the accuracy using this way of synchronisation is around 1
ms. The high accuracy of the LANTIME timeserver (around 10 microseconds) is
available by using the ATOM driver of the NTP subsystem, which is directly
interpreting the PPS (pulse per second) of the GPS reference clock. The default
configuration looks like this:
# *** lantime ***
# NTP.CONF for GPS167 with UNI ERLANGEN
server 127.127.1.0 # local clock
fudge 127.127.1.0 stratum 12 # local stratum
server 127.127.8.0 mode 135 prefer # GPS167 UNI Erlangen PPS
fudge 127.127.8.0 time1 0.0042 # relative to PPS
server 127.127.22.0 # ATOM (PPS)
fudge 127.127.22.0 flag3 1 # enable PPS API
enable stats
statsdir /var/log/
statistics loopstats
driftfile /etc/ntp.drift
# Edit /mnt/flash/ntpconf.add to add additional NTP parameters
90
Содержание LANTIME
Страница 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Страница 47: ...Configuration Ethernet 47...
Страница 52: ...Configuration Notification 52...
Страница 56: ...Configuration Security 56...
Страница 69: ...Configuration Local 69...
Страница 77: ...Configuration Statistics 77...
Страница 110: ...Rear View LANTIME 110...
Страница 111: ...SUB D Connector Assignments 111...
Страница 113: ...Accuracy of frequency TCXO quartz standard 113...
Страница 118: ...HUMIDITY Relativ humidity 85 max TEMPERATURE RANGE 0 60 Celsius POWER SUPPLY 5 V approx 330 mA 118...
Страница 132: ...Menu Quick Reference 132...
Страница 145: ...IRIG Standard Format 145...
Страница 146: ...AFNOR Standard Format 146...