SETUP SERIAL PORT
This menu lets the user configure the baud rate and the framing of the serial RS232
port to one of the following values:
Baud Rate:
300 to 19200
Framing:
7E2, 8N1, 8E1, 8O1
COM provides a time string once per second or once per minute.
Default:
COM: 19200 baud, 8N1, once per second
The following modes are possible:
Per Second:
Time string will be send to next change of second
Per Minute:
Time string will be send to next change of minute
On Request:
Time string will be send if an '?' will be send to this port
SETUP
SERIAL PORT
SERIAL PORT
PARM: 9600 8N1
MODE: Per second
SETUP SERIAL STRING TYPE
This topic is used to select one of several different types of serial time strings or the
capture string for each serial port.
The following time strings can be selected:
- Meinberg Standard String
- GPS167 Capture String
- SAT String
- UNI-Erlangen String
- NMEA String (RMC)
- SPA String
- Computime String
SETUP
SER. STRING TYPE
SER. STRING TYPE
COM: Meinbg Std
Refer to chapter
Time Strings
for details.
39
Содержание LANTIME
Страница 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Страница 47: ...Configuration Ethernet 47...
Страница 52: ...Configuration Notification 52...
Страница 56: ...Configuration Security 56...
Страница 69: ...Configuration Local 69...
Страница 77: ...Configuration Statistics 77...
Страница 110: ...Rear View LANTIME 110...
Страница 111: ...SUB D Connector Assignments 111...
Страница 113: ...Accuracy of frequency TCXO quartz standard 113...
Страница 118: ...HUMIDITY Relativ humidity 85 max TEMPERATURE RANGE 0 60 Celsius POWER SUPPLY 5 V approx 330 mA 118...
Страница 132: ...Menu Quick Reference 132...
Страница 145: ...IRIG Standard Format 145...
Страница 146: ...AFNOR Standard Format 146...