Technical specifications PZF5xx
RECEIVER:
Preamplifier with two post-connected receiver channels for best
aquisition and tracking of the DCF-signals.
CONTROL OF
RECEPTION:
The DCF-signal is checked for minimum field strength by
microprocessor. The result is indicated by LED.
In addition, the value of the digitized field strength is displayed
in menu 'FIELD'.
BATTERY-
BACKUP:
In case of power failure an internal realtime clock runs crystal-
precise. Important parameters are stored in the system-RAM.
Life time of lithium battery: 10 years minimum
Option: capacitance-backup for about 150 hours
INTERFACES:
Two independant asynchronous serial ports (internal RS232)
PULSE
OUTPUTS:
Active-high and active-low pulses per minute and per second,
TTL-level, pulse duration 200 ms
ACCURACY
OF PULSES:
Time delay of two systems PZF5xx with a maximum distance of
50 km: typ. 20 µs, max. 50 µs
Time shifting of successive pulses: max. 1.5 µs
PROPAGATION-
TIME
COMPENSATION: The signal delay is compensated if the distance of the receiver to
the transmitter is given.
STANDARD
FREQUENCIES:
10 MHz are synchronized to DCF by a digital PLL.
Accuracy in synchronized state: +/- 5·10-9 (short term stability)
Accuracy in unsynchronized state: 1·10-8 for one hour
77.5 kHz, 155 kHz und 310 kHz derived from receiver-PLL
Accuracy in synchronous state: +/- 5·10-7 (short term stability)
TERMINAL
CONNECTION:
Blade-connector strip VG64, DIN 41612
Sub-miniatur coaxial HF-connector (SMB internal)
BOARD
DIMENSIONS:
Eurocard size 100 mm x 160 mm, Epoxy 1,5 mm
Front panel 12TE (61 mm)
ANTENNA:
Ferrite antenna in plastic housing
117
Содержание LANTIME
Страница 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Страница 47: ...Configuration Ethernet 47...
Страница 52: ...Configuration Notification 52...
Страница 56: ...Configuration Security 56...
Страница 69: ...Configuration Local 69...
Страница 77: ...Configuration Statistics 77...
Страница 110: ...Rear View LANTIME 110...
Страница 111: ...SUB D Connector Assignments 111...
Страница 113: ...Accuracy of frequency TCXO quartz standard 113...
Страница 118: ...HUMIDITY Relativ humidity 85 max TEMPERATURE RANGE 0 60 Celsius POWER SUPPLY 5 V approx 330 mA 118...
Страница 132: ...Menu Quick Reference 132...
Страница 145: ...IRIG Standard Format 145...
Страница 146: ...AFNOR Standard Format 146...