SETUP TIME ZONE
This menu lets the user enter the names of the local time zone with daylight saving
disabled and enabled, together with the zones´ time offsets from UTC. The left part of
the display shows the zone and offset if daylight saving is off whereas the right part
shows name and offset if daylight saving is on. These parameters are used to convert
UTC to local time, e.g. MEZ = UTC + 1h and MESZ = UTC + 2h for central Europe.
The range of date daylight saving comes in effect can be entered using the next two
topics of the setup menu.
SETUP
TIME ZONE
TIME ZONE
Off«DAYL SAV-»ON
|MEZ | |MESZ |
+01:00h +02:00h
SETUP DAYLIGHT SAV ON/OFF
These two topics let the user enter the range of date for daylight saving to be in
effect. Concerning parameter input both topics are handled identically, so they are
described together in this chapter. Beginning and ending of daylight saving may
either be defined by exact dates for a single year or using an algorithm which allows
the receiver to re-compute the effective dates year by year. The figures below show
how to enter parameters in both cases. If the number of the year is displayed as
wildcards (´*´), a day-of-week must be specified. Then, starting from the configured
date, daylight saving changes the first day which matches the configured day-of-
week. In the figure below March 25, 1996 is a Saturday, so the next Sunday is March
31, 1996.
All changeover rules for the daylight saving like "the first/the second/the second to
last/the last Sunday/Monday etc. in the x-th month," can be described by the used
format "first specified day-of-week after a defined date".
If the number of the year is not displayed as wildcards the complete date exactly
determines the day daylight saving has to change (March 31, 1996 in the figures
below), so the day-of-week does not need to be specified and therefore is displayed as
wildcards.
SETUP
DAYLIGHT SAV ON
DAYLIGHT SAV ON
Date: 26.03.2000
Day of week ***
Time: 2:00:00
DAYLIGHT SAV ON
Date: 25.03.****
Day of week Sun
Time: 2:00:00
SETUP
DAYLIGHT SAV OFF
DAYLIGHT SAV OFF
Date: 29.10.2000
Day of week ***
Time: 3:00:00
DAYLIGHT SAV OFF
Date: 25.10.****
Day of week Sun
Time: 3:00:00
If no changeover in daylight saving is wanted, identical dates and times must be
entered in both of the submenus. In addition identical offsets for DAYLIGHT SAV
37
Содержание LANTIME
Страница 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Страница 47: ...Configuration Ethernet 47...
Страница 52: ...Configuration Notification 52...
Страница 56: ...Configuration Security 56...
Страница 69: ...Configuration Local 69...
Страница 77: ...Configuration Statistics 77...
Страница 110: ...Rear View LANTIME 110...
Страница 111: ...SUB D Connector Assignments 111...
Страница 113: ...Accuracy of frequency TCXO quartz standard 113...
Страница 118: ...HUMIDITY Relativ humidity 85 max TEMPERATURE RANGE 0 60 Celsius POWER SUPPLY 5 V approx 330 mA 118...
Страница 132: ...Menu Quick Reference 132...
Страница 145: ...IRIG Standard Format 145...