SNMP branch
Variable
Data type
Description
mbgLtCfgNtpServer3KEY
integer
Link to the key which should be used
for the third NTP-server
mbgLtCfgStratumLocalClock
integer(0..15)
Stratum-value of the internal system
clock of the timeserver
mbgLtCfgNTPTrustedKey
integer
Link to the key which should be used
for the internal reference time source
mbgLtCfgNTPBroadcastIP
string (IPv4 or IPv6-
address)
IP-address, which has to be used for
NTP-broadcasts (or multicasts)
mbgLtCfgNTPBroadcastKey
integer
Link to the key which should be used
for outgoing NTP-broadcasts
mbgLtCfgNTPBroadcastAutokey
integer (0 =
disabled, 1 =
enabled)
Use autokey for NTP broadcasts?
mbgLtCfgAutokeyFeature
integer (0 =
disabled, 1 =
enabled)
Use autokey feature of the NTP server?
mbgLtCfgAtomPPS
integer (0 =
disabled, 1 =
enabled)
Atom PPS (pulse per second) activated?
mbgLtCfgEMail
mbgLtCfgEMailTo
string (Liste von
EMail-addressn)
One or more (semicolon separated)
email address(es). which should receive
warnings and alarm notifications from
the timeserver
mbgLtCfgEMailFrom
string (EMail-
address)
The EMail-address which is used as the
senders address for email notifcations
mbgLtCfgEMailSmarthost
string (IPv4 or IPv6-
address or
hostname)
The SMTP-host, which is used for
sending mails
mbgLtCfgSNMP
mbgLtCfgSNMPTrapReceiver1
string (IPv4 or IPv6-
address or
hostname)
First host, which receives notifications
sent as SMTP-traps
mbgLtCfgSNMPTrapReceiver1Commu
nity
string
The SNMP community used when
sending SNMP-Traps to the first host
mbgLtCfgSNMPTrapReceiver2
string (IPv4 or IPv6-
address or
hostname)
Second host, which receives
notifications sent as SMTP-traps
mbgLtCfgSNMPTrapReceiver2Commu
nity
string
The SNMP community used when
sending SNMP-Traps to the second host
mbgLtCfgSNMPROCommunity
string
The SNMP community, which has read-
only access and therefore can be used to
only monitor status variables or
configuration values (SNMP V2c)
mbgLtCfgSNMPRWCommunity
string
The SNMP community, which has read-
write access and there for can be used to
monitor status variables and get/set
configuration values (SNMP V2c)
mbgLtCfgSNMPContact
string
Contact information (e.g. name of a
contact person) of the timeserver
mbgLtCfgSNMPLocation
string
Location (e.g. building/room number) of
the timeserver
mbgLtCfgWinpopup
mbgLtCfgWMailAddress1
string
First receiver of notifications sent as
windows popup messages
mbgLtCfgWMailAddress2
string
Second receiver of notifications sent as
windows popup messages
mbgLtCfgWalldisplay mbgLtCfgVP100Display1IP
string (IPv4 or IPv6-
address or
hostname)
hostname or IP-address of the first
wallmount display used for showing
notifications
mbgLtCfgVP100Display1SN
string (Hexstring)
The serial number of the first wall
mount display used for showing
notifications (can be found in the setup
menu of the display)
mbgLtCfgVP100Display2IP
string (IPv4 or IPv6-
address or
hostname)
hostname or IP-address of the second
wall mount display used for showing
notifications
mbgLtCfgVP100Display2SN
string (Hexstring)
The serial number of the first wall
mount display used for showing
notifications (can be found in the setup
menu of the display)
103
Содержание LANTIME
Страница 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Страница 47: ...Configuration Ethernet 47...
Страница 52: ...Configuration Notification 52...
Страница 56: ...Configuration Security 56...
Страница 69: ...Configuration Local 69...
Страница 77: ...Configuration Statistics 77...
Страница 110: ...Rear View LANTIME 110...
Страница 111: ...SUB D Connector Assignments 111...
Страница 113: ...Accuracy of frequency TCXO quartz standard 113...
Страница 118: ...HUMIDITY Relativ humidity 85 max TEMPERATURE RANGE 0 60 Celsius POWER SUPPLY 5 V approx 330 mA 118...
Страница 132: ...Menu Quick Reference 132...
Страница 145: ...IRIG Standard Format 145...
Страница 146: ...AFNOR Standard Format 146...