6-51
From now on, only the test parameters which have been specified as [set on device] under
WinkisVLF can be manually changed. This does also apply for the parameters accessible
via the setup menu (F2 key).
If the card is removed from the slot, the settings are undone and the standard start menu
appears on the display.
A cable test can be started as described in section 4.1.
Attention!
If the SystemCard is removed during an ongoing cable test, the test is
interrupted!
For the
special case
of a SystemCard intended to change the settings of the test system
permanently (see section 6.4.1), the settings (test parameter, print templates etc.) are
handed over and stored in the system right after the card has been identified as a “Proper
Card ?”. Afterwards, the start menu looks as follows and the card has to be removed from
the slot.
Fig. 35:
Start menu after new system settings have been stored
VLF mode
25kV
30min
F1:Print
F2:Setup
Card data stored.
Содержание TDS40