Single-coil Testing Using a Test Reference
This application involves setting up a new Test ID that will include a test reference to be used when testing other
devices of this type.
1. Connect the power pack’s test cables to a known-good coil as described in the table below.
Table 15:
Baker PPX30/30A device under test connections for single-coil Surge testing; reference coil.
Test Lead 1
Orange
Test Lead 2
Brown
Test Lead 3
Yellow
Ground Lead
Black
Black Braided
Safety Lead
Coil lead 1
Coil lead 2
Not Connected
Not Connected
Earth/station ground
Setting up the Test ID
1. Set the power pack’s
Function Selector
switch to
Surge
testing (surge icon).
2. Set the
Test Select
switch to
Lead 1
.
3. Set the
Ramp Rate
switch to 3 or 4 to start. You can adjust the rate as desired when testing the first coil.
4. Ensure that the
Zero-start Override
key switch is in the
Ramp
position (vertical—ZSO off).
Fig 33:
PPX30A Zero-start override key switch.
Item
Description
1
Zero-start override. This key switch overrides the Zero Start function and allows the unit to
immediately apply the full target voltage level to the test leads. With the key in the vertical
position, testing starts at zero volts and must be ramped up to the target voltage level.
2
In the horizontal key position, zero-start override is enabled. When the zero-start override
feature is enabled, target test voltage levels will be instantly applied to the test leads when a
test begins.
5. Create a separate Test ID and a Motor ID to use during the testing process. The Motor ID and Test ID can then be
re-used when testing other devices of this type.
6. During the Test ID setup, you will define a test reference.
7. Open the
Tests
tab.
8. Click on
Edit Test ID
.
9. Enter the password as needed.
10. Click on
Add
.
11. In the
Create New Test ID
dialog box, click on
Add Blank Test ID
.
12. Give the new Test ID a name that describes its function.
13. Enter the
Target Voltage Motor Class
then click
OK
.
14. Upon returning to the
Tests
tab, you should see the new Test ID displayed in the
Test ID
field.
15. Create a new Motor ID for the devices you will be testing. Be sure to select the new Test ID during the process.
Using Power Packs with Baker AWA Testers
www.megger.com 37
Содержание PPX30
Страница 1: ...Baker Power Packs PPX30 PPX30A PPX40 User Guide...
Страница 2: ......
Страница 6: ...Notices iv Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 12: ...Baker Power Pack Introduction 4 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 24: ...Baker Power Pack Setup 16 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 28: ...Using Power Packs with Baker AWA Testers 20 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 74: ...66 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 78: ...70 Baker Power Packs User Guide 71 061RC EN V2 www megger com...
Страница 82: ...74 Baker Power Packs User Guide 71 061RC EN V2 www megger com...