40
Change Start and Stop trigger sources for timer and hi-speed
capture modes:
striggerw,K,L;
works in any mode yet applies only to timer and hi-speed capture modes.
K
=start setting,
L
=stop setting:
0 for normally open contacts, latch off* 100 for normally open contacts, latch on*
1 for normally closed contacts, latch
off*
101 for normally closed contacts, latch on*
2 for voltage applied, latch off*
102 for voltage applied, latch on*
3 for voltage removed, latch off*
103 for voltage removed, latch on*
( * latch applies to timer mode only, for hi-speed capture a value of 100 is the same
as 0 ).
Sends external CT ratio setting:
sextctr;
format: “ ratio =1 or =200 or =600 or =1000 or =3000”
Change ( write ) external CT ratio setting:
sextctw,K;
K=1 or =200 or =600 or =1000 or =3000
Note:
You must re-issue the ‘m1, m3d, or m3y’ for the change
to be recognized.
Sends rms/average voltage setting:
srmsavgr;
This setting affects voltage readings in single and three phase ( wye and delta )
measure modes only
Changes rms/average voltage setting:
srmsavgw,K;
K= 0 for rms, K=1 for avg.
Hi-Speed Capture Specific: arm hi-speed capture function:
hscarm;
Timer Specific:
Timer reset:
treset;
Query Command
Transmits
all
measurement data on display in a comma delimited string. Each
string is terminated with a carriage return line feed.
Query readings:
qr;
The query response string format depends on current operating mode. If current
operating mode does not support a query “not in this mode you don’t” string will
be returned.
Modes supported:
1 phase, 3 phase ( wye or delta ), timer, and hi
speed capture. )
response formats:
1phase:
chan1, chan2,watts, vars, phase ( chan1 to
chan2 ), freq