1.
CAPTURE MODES:
Two capture modes are available:
-
AFTER-START:
in this mode a maximum of 60 seconds/1200
samples of data can be captured after the measurement is initiated.
Use the START inputs to initiate the measurement. The
measurement will automatically abort 60-seconds after it is started.
Other measurement options are: 15 seconds/300 samples and 30
seconds/600 samples.
-
NOTE:
Stop inputs can be used to terminate measurement.
- B
EFORE-STOP
: in this mode a maximum of 60 seconds of data
can be capture. Use the start inputs to initiate the measurement
and the STOP inputs are used to terminate the test.
4.8.1
THE
MEASURING
FUNCTIONS
1.
From
the
Main Menu
24
, press the
SINGLE-PHASE
function key.
2.
Select
HIGH SPEED CAPTR
from the Single Phase screen. The
following will appear:
Note that the information on top of the screen indicates the default
conditions for this mode.
3.
To
change
the
TRIGGER INPUT press the
TRIGR INPUT SELECT
function key. The following display will appear: