AVTMBITE 3 Rev 8 April 2014
31
APPENDIX A - Technical Specifications
Electrical
Impedance Range and Resolution
0.05 to 1.000 m
1
μ
resolution
1 to 10.00 m
10
μ
resolution
10 to 100.0 m
0.1 m
resolution
Voltage Range and Resolution
1 to 15 VDC across probes
1 to 8.0 V dc 1 mV resolution
8.0 to 15 VDC 10 mV resolution
Current Range and Resolution
Current:
0.5 – 9.99 A ac/dc
0.01 A resolution
10.0 – 99.9 A ac/dc 0.1 A resolution
Accuracy
dc voltage:
(1% rdg +1 lsd)
ac impedance: (5% of rdg +1 lsd)
current:
(5% rdg + 0.5 A)
Precision
Better than 0.5% one sigma
Source Output Current:
½
A rms
Display:
1/4 VGA LCD
Display Size:
2.83” x 2.95” (72mm x 57mm)
Settling Time per Reading:
approximately 6 to 8 seconds
Battery Pack:
2-3 hours continuous
4.8V dc, 7000 mAh, quick charge NiMH battery pack