Chapter 3 - Starting the Engine
Medha Servo Drives Pvt Ltd.
16
12. Turn the FP/ES switch lever to PRIME and hold it there (normally 10
- 20 sec, then release it) until the fuel flows clear and free from
bubbles in the return fuel sight glass.
13. Turn the FP/ES switch lever to ENGINE START and hold it there until
the Engine Starts and speed increases to Low Idle RPM 200. Do not
crank for more than 20 seconds.
14. After holding the engine RPM above 200 rpm, release the FP/ES
button.
15. Check Low water pressure detector reset button on EPD after Engine
starts. If the detector is not reset, the Engine shuts down after a short
time delay. If the detector trips, press continuously for 15 seconds.
Ÿ
If the Governor Booster pump is not provided on
Locomotive, Advance the Governor linkage Lay shaft
gently while cranking, till the Engine is running.
Ÿ
Verify that the Ground Relay CUTOUT Switch is closed
(lever up) and sealed properly. It is located on the Circuit
Breaker Panel.
Ÿ
Never discharge Batteries excessively by repeated cranking.
If first two or three attempts are failed, identify the fault
or check and reset safety devices like OSTA/LLOB etc. If
any one is tripped, recheck cranking procedure.
Ÿ
Ensure that MU Engine Stop button is not operated in
the consist Locomotives.
Ÿ
Follow the correct Cranking and Shutdown procedure to
enhance Engine and Turbo life.
N
O
T
E
To prevent over heating of starting Motors, which may damage
them, do not allow Engine cranking for more than 20 seconds.
If Engine fails to start after cranking for 20 seconds, wait for 2
minutes to cool starting Motors before cranking Engine again.
C
A
U
T
IO
N