27
Medha Servo Drives Pvt Ltd.
MAS 696 Operator’s Manual
8.
FILTER BWR MTR Circuit Breaker:
This 30A circuit Breaker
protects the Inertial Filter Blower Motor circuit.
9.
AUX GEN FIELD Circuit Breaker:
This 10A circuit Breaker protects
the Auxiliary Generator Field circuit and it is equipped with auxiliary
contact sets. One set is double pole switch that protects the AG PWM
circuit.
10.
FUEL PUMP Circuit Breaker:
This 30A circuit Breaker protects the
Fuel Pump Motor Circuit.
11.
TURBO Circuit Breaker:
This 30A circuit breaker provides power
and protection to the Turbo Lube pump Motor. It must be switched
ON before Engine start for pre lube and after Engine shutdown to
remove residual heat from the Turbo bearings. If the Engine is
running and this breaker is OFF, the TURBO CIRCUIT BREAKR IS
NOT CLOSED message appears on the Display.
12. COMPTR CONTROL Circuit Breaker:
This 15A Circuit Breaker
protects the Locomotive Control Computer operating power supply.
13.
MICRO AIR BRAKE Circuit Breaker:
This 15A Circuit Breaker
provides operating power to the KNORR Air Brake system and the
Air Brake system cooling Fans.
If the Filter Blower Motor breaker trips, continue Locomotive
operation to the nearest maintenance point.
N