![Medha MAS 696 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/medha/mas-696/mas-696_operators-manual_1760028043.webp)
43
Medha Servo Drives Pvt Ltd.
MAS 696 Operator’s Manual
AIR BRAKE EQUIPMENT:
1. Set Air Brake controller Automatic Brake Handle in FS (full service).
This nullifies any safety control brake application.
2. Set Air Brake controller Independent Brake valve Handle in FULL (full
application)
3. Set Air Brake controller setup (LEAD/TRAIL SWITCH) in LEAD
position.
TRAILING LOCOMOTIVE CAB INSPECTION:
Check the following trailing Locomotive cab device settings, correct them as
required:
STARTING FUSE AND BATTERY BOX:
1. Verify that main Battery Knife is closed.
2. Verify that Staring Fuse is installed in good condition and is of correct
rating.
10.2 Starting Lead Locomotive Engine
The Diesel Engine may be started after the following inspection have been
completed:
ENGINE INSPECTION:
1. Ensure Throttle Handle of both control console is in IDLE, Reverser
handle is at center and RUN/ISOLATE Switch is in ISOLATE
position.
2. Ensure there is sufficient oil level in Compressor oil, Engine sump
Lube Oil and Governor Oil.
3. Ensure there is sufficient Coolant Water level in the water tank
(Engine dead – Full).
4. Ensure no one is working on the Engine, Generator Room,
Compressor Room etc. and all the doors are closed.
5. Ensure the MU Engine Stop button is in RUN position (For reset
press Green portion inside)
6. Ensure the engine over speed mechanism is reset.
7. Ensure the Governor Low Lube Oil Button (LLOB) is reset.
8. Ensure that the Crankcase (oil pan) pressure and Low water
pressure detector reset buttons are reset (pressed in side). If the
button is ejected, press and hold it for 5 seconds immediately after
Engine starts.