62
Medha Servo Drives Pvt Ltd.
MAS 696 Operator’s Manual
Message
Code
Message Text
1081
No Engine Start – Turbo pump not running Run pump for 15
minutes.
125
No Load – Locomotive is Isolated.
179
No Load – Improper GFC contactor status – Cycle Computer
Control CB.
192
No Load – Improper B3 contactor status – Cycle Computer Control
CB.
193
No Load – Improper B1 contactor status – Cycle Computer Control
CB.
1815
No Load – Improper B2 contactor status – Cycle Computer Control
CB.
616
No Load – Improper B4 contactor status - Cycle Computer Control
CB.
200
No Load – Improper GFD contactor status – Cycle Computer
Control CB.
220
No Load – Fuel pump is not running.
602
Reduced Load – TCC 1 Blower Circuit Breaker is not closed.
602
Reduced Load – TCC 2 Blower Circuit Breaker is not closed.
602
Reduced Load – TCC 3 Blower Circuit Breaker is not closed.
603
Reduced Load – TCC 4 Blower Circuit Breaker is not closed.
603
Reduced Load – TCC 5 Blower Circuit Breaker is not closed.
603
Reduced Load – TCC 6 Blower Circuit Breaker is not closed.
617
No Load – Improper DCL 1 Status – Cycle Computer Control CB.
617
No Load – Improper DCL 2 Status – Cycle Computer Control CB.
617
No Load – Improper DCL 3 Status – Cycle Computer Control CB.
617
No Load – Improper DCL 4 Status – Cycle Computer Control CB.
617
No Load – Improper DCL 5 Status – Cycle Computer Control CB.
617
No Load – Improper DCL 6 Status – Cycle Computer Control CB.
637
No Load – No CA output Check Aux.Gen.Field Circuit Breaker.
986
No Governor Boost – Improper Relay Status.
996
No Aux.Gen. Output - Check Aux.Gen. Field circuit breaker.
2616
No Aux Power – Control Circuit Breaker is not closed.
2354
No Lubrication allowed Turbo Lube Pump Circuit Breaker is not
closed.
2495
No Power – Locomotive speed too high bring MCH to Idle.
3315
No Dynamic Brake – DB Circuit Breaker is not closed.
2654
Reduced Dynamic Brake/Load Test – No Grid Blower 1 current
imbalance.