![Medha MAS 696 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/medha/mas-696/mas-696_operators-manual_1760028060.webp)
60
Medha Servo Drives Pvt Ltd.
MAS 696 Operator’s Manual
Message
Code
Message Text
5094
FDB Power supply failure.
2060
B1 contactor failed to pickup.
2062
B2 contactor failed to pickup.
2051
B3 contactor failed to pickup.
2049
B4 contactor failed to pickup.
5109
Blended Brake Cutout.
2671
Coupled Locomotive detected-Tractive Effort limited.
3320
Cold Engine Throttle 2 limit.
794
DCL 1 Control Circuit Breaker is not closed.
794
DCL 2 Control Circuit Breaker is not closed.
794
DCL 3 Control Circuit Breaker is not closed.
794
DCL 4 Control Circuit Breaker is not closed.
794
DCL 5 Control Circuit Breaker is not closed.
794
DCL 6 Control Circuit Breaker is not closed.
5095
Dynamic Brake Cutout.
14
Engine Air Filters are Dirty – Change out request power may limit
to TH6.
66
Engine Dead – Locomotive is not Isolated.
67
Emergency Fuel Cutoff activated.
76
Engine speed Increases – Turbo Cool down cycle.
77
Engine speed Increases – Air Compressor operation.
341
Engine Speed increases – Traction Motor over Temperature.
716
Engine Dead while Loading.
937
Engine Dead with cold water.
994
Engine shutdown – Engine oil pressure.
1104
Engine speed Increases – High Aux. Generator Load.
1227
Engine will not start – Low Engine water level detected.
1056
Engine shutdown – Engine over speed.
3319
Engine shutdown – low water level.
5065
Engine speed Increases – Hot Engine.
93
Filter Blower Circuit Breaker is not closed.
96
Forced minimum Engine speed – Engine Run switch is down.
136
Forced minimum Engine speed – Locomotive is Isolated.
221
FP Relay failed to pickup.
296
Fuel Pump is not running-check FP Relay and Circuit Breaker.
352
FP Relay failed to drop out.