2 - COMPONENTS AND CONTROLS
1) OIL WARNING SYSTEM (PIC. 2)
When the oil level falls below the minimum level, the engine
will stop automatically. The engine will not start again until it
has been refilled with oil.
2) ENGINE SWITCH (PIC. 3/A)
The engine ON/OFF switch controls the ignition system.
1) «ON»(run)
Ignition circuit is switched on. The engine can be started.
2) «OFF»(stop)
Ignition circuit is switched off. The engine will not run.
3) «START» (only for models: NPEGG3800/5200/6000/7500)
Starting circuit is switched on. The starter motor starts.
3) AC CIRCUIT PROTECTOR (PIC. 3/A)
The AC Circuit Protector turns on automatically when the load
exceeds the maximum rated output.
CAUTION:
Reduce the load to within specified generator
rated output if the AC Circuit Protector turns on.
DESCRIPTION (PIC. 4/A - 4/B)
(1) Fuel tank
(2) Fuel tank cap
(3) Fuel cock
(4) Air filter cover
(5) Spark plug
(6) Muffler
(7) Choke lever
(8) AC socket (NPEGG7500: 1 x 230V, 1 x 400V)
(9) Engine switch
(10) Ground (earth) terminal
(11) Oil filler cap
(12) Oil drain plug
(13) Recoil starter handle
(14) AC Protector
(15) Pilot light
(16) Oil warning lamp (only for NPEGG850)
(17) Voltmeter
(18) AC switch
(19) DC circuit breaker
(20) DC socket
3 - PRE-OPERATION CHECK
NOTE:
PRE-OPERATION CHECKS SHOULD BE MADE EACH
TIME THE GENERATOR IS USED.
1) CHECK ENGINE FUEL (PIC. 5)
• Check fuel level at fuel level gauge.
• If fuel level is low, refill with unleaded automotive gasoline.
• Be sure to use the fuel filter screen in the fuel filter neck.
• Recommended fuel:
Unleaded gasoline
.
WARNING:
• Do not refill tank while engine is running or hot.
• Close the fuel cock before refueling with fuel.
• Be careful not to allow dust, dirt, water or other foreign objects
into the fuel.
• Wipe off spilt fuel thoroughly before starting engine.
• «F» full, «E» empty.
2) CHECK ENGINE OIL (PIC. 6)
Before checking or refilling with oil, be sure that the generator is
put on a stable and level surface with the engine stopped.
• Remove oil filler cap (A) and check the engine oil level.
• If oil level is below the lowr level line (B) , refill with suitable
oil to max level line (C). Do not screw in the oil filler cap when
checking oil level.
• Change the oil if contaminated.
• Recommended engine oil:
API Service «SE» or «SF», if not available, «SD».
3) GROUND (EARTH) (PIC. 1)
Make sure to ground (earth) the generator.
4 - OPERATION
NOTE: THE GENERATOR HAS BEEN SHIPPED WITHOUT
ENGINE OIL. FILL WITH OIL OR IT WILL NOT START.
1) STARTING THE ENGINE
NOTE:
• Do not connect the electric load or equipment before starting
the engine,.
• Turn the AC switch to «OFF». (PIC. 7) (not available on
model NPEGG850)
1. Turn the fuel cock lever to «ON». (PIC. 8)
2. Turn the engine switch to «ON». (PIC. 9)
3. Turn the choke lever to the “closed” position. Not necessary
if the engine is warm. (PIC. 10)
4. Pull the starter handle slowly until resistance is felt. This is
the «Compression» point. Return the handle to its original
position and pull swiftly. Do not fully pull out the rope. After
starting, allow the starter handle to return to its original
position while still holding the handle. (PIC. 11)
5. Allow the engine to reach operating temperature.
6. Turn the choke lever back to the operating position. (PIC.
12)
7. Warm up the engine without a load for a few minutes.
2) USING ELECTRIC POWER
1 - AC APPLICATION (SINGLE VOLTAGE TYPE)
(a) Check the indicator lamp or the voltmeter for correct
voltage.
(b) Ensure that electrical equipment is switched off before
connecting to the generator.
(c) Connect the plug(s) of the electrical equipment into the
appropriate socket.
(d) Turn the AC switch (not available on model NPEGG850)
to the «ON» position and turn on the electric equipment. (PIC.
13)
CAUTION:
• Be sure the total load is within generator rated output.
• Be sure the socket load current is within socket rated
current.
• To take out power from TWIST LOCK receptacle, insert the
plug into receptacle and turn clockwise to lock it.
27
GB
2 - AC APPLICATION (DUAL VOLTAGE TYPE) (FIG. 3/B)
(OPTION)
(a) Select the correct voltage using the AC OUTPUT SELECT
SWITCH to the same as the rating for the appliance.
(b) Operate in the same way as step (a) through step (d) of
single voltage type.
NOTE: Voltmeter always indicates the lower voltage
whichever the AC OUTPUT SELECT SWITCH is set.
3 - DC APPLICATION (OPTION)
This usage is applicable to 12V battery charging only.
(a) Charging instruction for battery
• Disconnect the leads of the battery.
• Loosen the battery top up caps to prevent the build up of
pressure during chatrging.
• If the battery fluid level is low , top up the battery with distilled
water to the upper limit,.
• Measure the specific gravity for the battery fluid by using the
hydrometer, and calculate the charging time in accordance
with the table shown on right side.
• The specific gravity for the fully charged battery shall be
within 1.26 to 1.28.
(b) Connect the DC output socket and to the battery terminals
using the charging leadsMake sure that the leads are
connected the correct way round (+) and (-) polarity.
(c) The DC circuit breaker should to be set to the «ON»
position.
3 - STOPPING THE ENGINE (PIC. 14)
1. Turn off the power to the electric equipment or unplug the
mains lead from socket of the generator. Turn the AC switch
to «OFF».
2. Turn the engine switch to «OFF».
3. Turn the fuel cock lever to «OFF».
4 - BATTERY (NOT INCLUDED) CONNECTION FOR
ELECTRIC STARTING SYSTEM
(ONLY FOR MODELS NPEGG3800/5200/6000/7500)
1. REPLENISHING THE BATTERY FLUID
• Check the fluid level. The level should be between the upper
and lower level marks.
• Add only distilled water if necessary.
2. BATTERY STORE
Remove the battery and charge it. Store it in a dry place
and recharge it once a month. Do not store the battery in an
excessively warm or cold place.
3. RECOMMENDED BATTERY
• Recommended battery: 12V/26A·h
4. OPERATIONS (PIC. 22)
• Clamp the wires (included) to the generator. Black wire (-) to
Earth (A) and red wire (+) to the starting motor (B).
• Clamp the red wire to the positive (+) terminal and the black
wire to the negative (-) terminal of the battery. Do not reverse
these positions.
• Be sure the battery is installed on the battery mount tray
securely.
• Perform “Starting the Engine” actions (Chapter 4 – Operation).
With this system there’s no need to use the recoil starter
handle, to start the generator just turn the key of the engine
switch (C) to the position “START”.
SPECIFIC GRAVITY AND CHARGING TIME CHART
Specific gravity
BATTERY CAPACITY
1. 30AH 20 HR
2. 35AH 20 HR
3. 47AH 20 HR
Charging time (Hours)
5 - PERIODIC MAINTENANCE
1) MAINTENANCE CHART
Regular maintenance is important for the best performance and safe operation.
Warning: Use protective gloves for the following operations.
ITEM
REMARKS
Pre -
operation
check (daily)
Initial
1 month
or 20 Hr
Every
3 months
or 50Hr
Every
6 months
or 100Hr
Every
12 months
or 300Hr
Spark Plug
Check condition adjust gap and
clean.
Replace if necessary.
•
Engine Oil
Check oil level
•
Replace
•
•
Содержание MF6500E
Страница 9: ...1 2 3 9...
Страница 11: ...11...
Страница 12: ...12 12 14 15 16 17...
Страница 13: ...13 13 18 19 20 21...
Страница 14: ...14...
Страница 145: ...145 137 BG a 24...
Страница 146: ...146 138 BG 1 1 1 SJ SJO 1 5 60 2 5 100 0 12 0 005 10 1 2...
Страница 149: ...149 141 BG NPEGG3800 5200 6000 7500 1 2 3 12V 26A h 4 22 4 Start 5 1 20 3 50 6 100 300...
Страница 151: ...151 143 BG 6...
Страница 152: ...152 144 BG 60 Hz 3780 50 Hz 3150 1 2 3 7 30 21 1 2 3 4 3 4 1 5...
Страница 154: ...154 146 BG ISO 8528 EN ISO 3744...