4.1.2 Central function
The following illustration shows the setting options at the ETS-Software:
Figure 3: Central function
The following chart shows the dynamic range for this parameter:
ETS-text
Dynamic range
[default value]
comment
Central function
not active
active
switches the central function
on/off for this channel
Table 5: Central function
The central function can be switched on/off for every channel. For switching on this function, you
have to choose the option
a ti e . By alli g the e tral o
u i atio o je t, all ha els ith a
activated central function are switched on with their current parameterization. So switch-on delays
or staircase functions are still kept.
The central function can make programming much more easier and your project can become more
clear.
The following chart shows the associated communication object:
Number
Name
Length
Usage
16
Central function
1 Bit
central switching of the channels
number depends to the number of channels
Table 6: Communication object central function
4.1.3 Behavior at block/unblock
The following illustration shows the setting options at the ETS-Software:
Figure 4: Blocking function
The following chart shows the dynamic range for this parameter:
ETS-text
Dynamic range
[default value]
comment
Behavior when locked
Behavior when unlocked
On
Off
no change
Behavior to a
blocking/unblocking process
Table 7: Behavior at block/unblock