86
LEDR Series I/O Guide
MDS 05-3627A01, Rev. D
This command is used to display continuously updated readings of:
RSSI, radio temperature, RF output, signal-to-noise ratio, and FEC
errors (corrected and uncorrectable). The display can be stopped by
pressing Control-C on the terminal.
If the
trend
command is used by itself or with
all
(
trend all
), all associated
parameters will be reported. More than one argument can be used to dis-
play several selected items in the desired order.
NOTE:
This command is not available from a Telnet session.
txkey
Radio Transmitter Keying Status
Usage:
txkey [on|off]
This command sets or displays the radio transmitter status. ON indicates
the radio transmitter is keyed and transmitting.
OFF
indicates the trans-
mitter is not keyed.
unitid
Unit Identification Number for Orderwire and NMS
Usage:
unitid [<ID>]
This command sets or displays the radio’s unit identification number.
This number is used for Orderwire signaling and by the NMS (Network
Management System). (See “USING ORDERWIRE” on Page 99.) The
factory default is the last three numbers of the unit serial number.
(1-999)
uptime
Up Time
Usage:
uptime
This command displays how long the radio has been powered-on.
user
User Account Information
Usage:
user [subcommand] [<argument>]
Subcommands:
add <user> <pass> <perm>
del <user>
perm <user> <perm>
pass
This command provides administrator access for setting new user
accounts and permission levels.
NOTE:
The password (
pass
) and user names are case sensitive and
may not exceed eight characters. Two quotation mark charac-
ters ("") may be used as a “blank” password. If quotation
marks are used, the shift key or cap lock keys must be
depressed.