![MDS LEDR 1400F Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/mds/ledr-1400f/ledr-1400f_installation-and-operation-manual_1757407083.webp)
MDS 05-3627A01, Rev. D
LEDR Series I/O Guide
75
NOTE:
The associated radio (sibling) IP address should be
programmed to the IP address of the other radio connected to
the Protected Switch Chassis. The associated radio IP address
is used by the redundant radio to share information between
the units. This address is necessary for warm-standby
switching. The associated radio IP address parameters do not
affect IP routing and forwarding, SNMP, or Telnet.
The
rdnt swxcvr
will not operate correctly if this parameter is
not set correctly.
mode [#]
—Set or display one of three redundant operation modes
(
0
= Standalone,
1
= 1+1 Hot Standby,
2
= 1+1 Warm Standby).
status
—Shows the state of both radios. Two status lines are displayed;
This Radio
and
Other Radio
.
swxcvr
—Forces a switchover to the inactive radio transceiver. (The
newly selected unit becomes the active transceiver.) The
rdnt ip
param-
eter must be configured correctly on both radios in order for the
swxcvr
command to operate correctly.
NOTE:
The
rdnt swxcvr
command should not be used within 2 minutes
of a power-up to ensure reliable communications exist
between the two transceivers.
temp
—Set or display an over-temperature threshold (final amplifier
temperature in degrees Celsius), at which temperature switchover to the
other radio occurs.
nsd
—Enable or disable network self-discovery between the units in a
protected pair
Example Response for
rdnt
command:
rdnt {status}: This Radio = OK
rdnt {status}: Other Radio = OK
rdnt {active}: inactive
rdnt {mode}: 1+1 Hot Standby
rdnt {ip}: 10.2.233.12
rdnt {hitless}: on
rdnt {default}: no
rdnt {temp}: 50
rdnt {nsd}: on
reframe
Reframe Criteria for User Interface Ports
Usage:
reframe [linelist] [2of4 | 2of5 | 2of6 | CFAS | CRC]
This command is used to set or display the reframe criteria. The
[linelist]
variable represents a list of line interfaces. It can consist of a single line
number or linename, a comma separated list of line numbers or line
names, a range of line numbers (i.e., 1–4), or if linelist is not given all
lines. See
on Page 59 for a list of line numbers.
E1
FT1
FE1