24
LEDR Series I/O Guide
MDS 05-3627A01, Rev. D
3.8 Transmit Clock Selection
(Subrate Radios Only)
For a subrate radio, transmit clock arrangement must be set by the user.
Clocking arrangements for fullrate radios is automatically handled by
the LEDR radios.
It is essential that there be only one master clock in a subrate radio net-
work. The master clock can originate from the radio or from the Cus-
tomer Premises Equipment (CPE).
LEDR radios are capable of several different clocking modes. Refer to
for typical system clocking arrangements.
Refer to the
CCC
Clllloooocccckkkk MMMMooooddddeeee
for setting the
radio transmit clocking from the front panel. Refer to the
clkmode
for setting the radio transmit clocking mode from
the front panel
CONSOLE
Port.
NOTE:
When customer premises equipment (CPE) is operated in
looped clock mode, it is recommended that the radio not be set
to line clock mode. To do so may cause the transmitting
radio’s PLL to be pulled out-of-lock, especially when oper-
ating at 4E1 data rates.
Table 11. Fullrate Bandwidth vs. Modem Selection Code
Radio
Bandwidth
Configuratio
n Code
Data
Rate(s)
Modulation
500 kHz
C7
E1
32-QAM
1000 kHz
B7
E1
16-QAM
C7
E1
32-QAM
C8
2E1
32-QAM
2000 kHz
A7
E1
QPSK
B7
E1
16-QAM
B8
2E1
16-QAM
C8
2E1
32-QAM
C10
4E1
32-QAM