28
LEDR Series I/O Guide
MDS 05-3627A01, Rev. D
using the
user
for complete description of
user
command.
NOTE:
It is recommended that users log out when finished using the
front panel navigation keys or console terminal. This can be
done using the
Logout
screen on the radio, or the
logout
command from a console terminal as appropriate. If there is no
key or terminal activity for 10 minutes, the radio automatically
logs out and reverts to read-only status.
4.6 STEP 5—Review Essential Operating
Parameters
Review and set the following parameters to allow data throughput and
interconnection with the network. These are radio operating frequen-
cies, data interface clocking, and data framing.
outlines these
based on each model group and configuration.
Table 12. Essential Parameters for Standalone & Protected
Model
Group
Data
Interface
Parameter
Setting
Subrate
EIA-530
RF TX/RX
Frequency
Factory configured for customer
frequencies.
Clocking
Use clkmode command (
to match interface equipment.
Framing
Does not apply.
FT1/FE1
RF TX/RX
Frequency
Factory configured for customer
frequencies.
Clocking
Automatically set to match
connected equipment.
Framing
Set as appropriate using fstruct
command (
).
Time Slot
Set as appropriate using timeslot
command (
).
Line Code
Set as appropriate using linecode
command (
).
Fullrate
E1
RF TX/RX
Frequency
Factory configured for customer
frequencies.
Clocking
No settings are necessary. Radio
automatically detects clock and sets
mode.
Framing
• Radio set to unframed (default).
• Make changes as appropriate
using fstruct command
(
equipment.
Line Code
Set as appropriate using linecode
command (
).