74
LEDR Series I/O Guide
MDS 05-3627A01, Rev. D
rdnt
Redundant (Protected Operation)
The
rdnt
command is used to manage protected operation of the LEDR
radio and display operating status.
Usage:
rdnt [subcommand] [arguments]
Subcommands:
active
default
hitless
ip
mode
nsd
status
swxcvr
temp
mode
The following subcommands are divided into two groups: read only and
read and set.
Read Only:
active
—Shows whether the currently selected transmitter is active or
inactive.
default
—Displays whether the radio is the default radio in a protected
configuration.
status—
Protected status of this radio and the sibling radio.
Read & Set:
hitless
—Sets or displays the hitless (error-free) switching status of the
receivers. It can be enabled or disabled using the
hitless on|off
command.
In protected operation, either receiver (regardless of which transmitter
is active) can provide data to the user data port(s) in hitless mode. In
non-hitless mode, only the receiver in the active radio provides received
data. Radios operated in a space-diversity configuration must be config-
ured to use hitless switching.
ip
—Used to set or display the IP address to be kept in the memory of this
unit of the associated (sibling) radio in a redundant pair of transceivers.
In other words, the
rdnt ip
setting of the top radio in a protected pair must
be set to the bottom radio’s IP address for proper switching and net-
work-management functionality.