MDS 05-3627A01, Rev. D
LEDR Series I/O Guide
131
NOTE:
The event codes listed here are available on radios equipped
with the optional FT1 Interface Board. Standard “S” Series
radios will display fewer codes.
Table 33. Event Codes
ID
EVENT NAME
DESCRIPTION
DEFAULT
LED
SNMP
TRAP
LEVEL
0
EXT_ALARM_IN1
External Alarm Input #1
ALARM
CRITICAL
1
EXT_ALARM_IN2
External Alarm Input #2
ALARM
CRITICAL
2
EXT_ALARM_IN3
External Alarm Input #3
ALARM
CRITICAL
3
EXT_ALARM_IN4
External Alarm Input #4
ALARM
CRITICAL
4
MODULATOR_EV
Communication failure
with modulator
ALARM
CRITICAL
5
DEMODULATOR_EV
Communication failure
with demodulator
ALARM
CRITICAL
6
MOD_SELFTEST
Modulator selftest failed
NONE
CRITICAL
7
DEMOD_SELFTEST
Demodulator selftest
failed
NONE
INFORM
8
PERM_REGN_CHECKSUM
Permanent region
checksum failed
NONE
INFORM
9
APP1_REGN_CHECKSUM
Application #1 checksum
failed
NONE
INFORM
10
APP2_REGN_CHECKSUM
Application #2 checksum
failed
NONE
INFORM
11
BOOT_REGN_CHECKSUM
Boot loader checksum
failed
NONE
INFORM
12
CONF1_REGN_CHECKSUM
Configuration Data region
#1 checksum failed
NONE
INFORM
13
CONF2_REGN_CHECKSUM
Configuration Data region
#2 checksum failed
NONE
INFORM
14
RTC_TEST
Real-time clock error
NONE
INFORM
15
BBRAM_TEST
NV-RAM test failed
NONE
INFORM
16
BATTERY_LOW
NV-RAM battery is low
ALARM
MAJOR
17
TX_SYNTH_LOCK
Transmit Synthesizer
out-of-lock
TXALARM
CRITICAL
18
RX_SYNTH_LOCK
Receive Synthesizer
out-of-lock
RXALARM
CRITICAL
19
DIG_POWER_REF
Digital Power Reference
is out of specified range
ALARM
CRITICAL
20
TEMPERATURE
Temperature sensor
reads over 80 degrees
Celsius
ALARM
CRITICAL
21
TX_POWER_LOOP
Transmit Power Loop is
out-of-lock
TXALARM
MAJOR
22
DEMOD_SNR_LOW
Demodulator
Signal-to-Noise ratio is
unacceptably low
NONE
MINOR