26
2. Canceling double feed detection (System constant A)
There is a rare possibility that the sensitivity of the paper feed photo sensor may not be fitted to paper by
adjusting the paper feed photo sensor with the system constant P. At this time, cancel double feed detection
to attain a paper feed as a temporary measure.
Double feed detection can be canceled by setting the system constant A.
Indication
Counter Contents
of
indication
Operation Remarks
1000 digit
A
-
100 digit
All-station double feed
detection ON/OFF
Switch with the “1” key.
“1”: Double feed detection ON
“0”: Double feed detection OFF
10 digit
Individual station
indication
Increment the station by 1 with
the “2” key
Decrement the station by 1 with
the “8” key
1 digit
Individual-station double
feed detection ON/OFF
Switch with the “3” key.
“-“ is indicated at whole double
feed detection OFF.
3. Changing the paper feed wait time at connection of an option (System constant L)
When a post-process machine such as a booklet maker is connected, the paper feed cycle of collator may be
made shorter or longer in some cases. In these cases, the time from the passage of paper through the paper
feed photo sensor at the end till the execution of the next paper feed (*1) at collator side can be adjusted in
the range of 0 to 60 seconds by operating the system constant L.
*1: In case of paper ejection to the booklet maker (in case of connection with KAS or Plockmatic booklet
maker) without control, the electric signal is not communicated between the collator and the booklet
maker. Therefore, the paper feed waiting time (L value) is directly reflected. On the other hand, in
case of paper ejection to the booklet maker with electric signal Communication (in case of Foldnak
booklet maker), the time after a paper eject response signal output from Foldnak until the next paper
feeding starts is set as the paper feed waiting time (L value).
Indication
Counter Contents
of
indication
Operation Remarks
1000 digit
L
-
100 digit
10 digit
1 digit
Paper feed wait time
Ten-key
Ten-key
4. A left error occurs though a normal process has been performed when using a large-capacity
stacker or Foldnak. (System constant n)
In a machine such as a large-capacity stacker and Foldnak that returns a paper ejection response to the
collator, a left (option device) error may be caused to the collator though the paper process has been
normally performed.
Содержание FC-10
Страница 2: ... 1 1 ...
Страница 14: ...13 6 WIRING DIAGRAM ...
Страница 15: ...14 7 CIRCUIT BOARD DIAGRAM 7 1 Operation board ...
Страница 16: ...15 7 2 Speed control circuit board ...
Страница 18: ...17 9 DIAGRAM FOR BELT INSTALLATION ...