23
11.3 Releasing double feed detecting function
In case double feed cannot be detected since paper used is too thick (Err3), collation can be continued by
canceling double feed detection function.
(1) Press [0] key for three seconds ( [ P x ] will be displayed).
(2) Press the [MODE] key to display [A xxx] ( xxx represents the current set value).
(3) Press the [1] key to display “0” in the third digital figure.
(4) Press the CHECK key or START key to reflect the change.
Press the CHECK key for temporary setting
(The set value will return to the initial value when the power supply is cut off).
Press the START key to memorize the set value
(The altered value will be stored even if the power supply is cut off).
11.4 Initializing the system constant (return to factory-set value)
In case the machine work becomes unstable after the system constants are altered for adjustment, the
system constant can be returned to the factory-set values.
(1) Turn off the power of the collator.
(2) While pressing the CLEAR key, turn on the power.
Caution!
With this initializing procedures, all set values including those for Insert and Chit modes are deleted
and returned to the factory-set values.
Necessary data should be jotted down before deletion and used for re-setting.