MaxPac Single/Dual/Triple-Screen 8230 Training and Maintenance Guide
Figure 3-47
Figure 3-48
3) Use the up/down arrow keys to highlight disks 00, 01, and 02 in turn; as each disk is highlighted,
press the <Enter> key to select it (selected disks are indicated with an asterisk '*' character as
shown in Figure 3-48). (Note that the reason disk 03 is not selected is that this is being reserved
as the hot-spare.)
4) Use the <Tab> key to highlight the
Create Unit
option (Figure 3-48), then press the <Enter> key
to key to invoke the Create Disk Array screen.
5) Use the up/down arrow keys to highlight the
RAID Configuration
item, and then press the
<Enter> key to access an associated pop-up dialog (Figure 3-49).
6) Now use the up/down keys to highlight the
RAID 5
option and then press the <Enter> key to
select this option.
Figure 3-49
Figure 3-50
7) Next, use the up/down arrow keys to highlight the
Stripe Size
item, and then press the <Enter>
key to access an associated pop-up dialog (Figure 3-50).
8) Use the up/down arrow keys to highlight the
256 KB
option, and then press the <Enter> key to
select this option.
9) Use the up/down arrow keys to highlight the
Write Cache Setting
item, and then press the
<Enter> key to access an associated pop-up dialog (Figure 3-51).
10) Use the up/down arrow keys to highlight the
Enabled
option, and then press the <Enter> key to
select this option.