13
Matrix SETU VFXTH System Manual
Powering ON SETU VFXTH
•
Connect the power adapter into the power jack, and plug it into a power outlet.
•
Switch ON power supply and observe the reset cycle.
LED Indication
At Power ON, Power LED will turn ON (Continuous Green). Initialization process will start within 15 to 20 seconds
and LED sequence of all other LEDs during initialization process is shown in the table given below:
During initialization, System LED (STS) will display following error/events/status:
System Status
Color
STS
P01
P02
P03
P04
P05
P06
….
P32
Time
(ms)
Application Load
Red
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
All Init Done,
System goes
Live
Red
ON
ON
ON
ON
ON
ON
ON
ON
ON
1000 ms
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1000 ms
LED Status
Colour
Comment
Continuous On
Red
VoPP program download fail / Port
not detected / System Error.
2000 ms On (Red)
5000 ms On (Green)
Red and Green
Modules not detected.
1sec On - 1sec Off
Green
SETU VFXTH started successfully.
Network link is Up.
SIP stack is Up.
CDR buffer is not full.
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 500ms off (4 Blinks)
Green
Network link is down.
SIP stack is down.
CDR buffer is not full.
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 1500ms off (3 Blinks)
Green
Network link is Up.
SIP stack is down.
CDR buffer is not full.
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 500ms off (4 Blinks)
Red
Network link is down.
SIP stack is down.
CDR buffer is full.
1sec On - 1sec Off
Red
Network link is up.
SIP stack is down.
CDR buffer is full.
500 ms on - 500ms off -
500 ms on - 500ms off -
500 ms on - 1500ms off (3 Blinks)
Red
Network link is up.
SIP stack is up.
CDR buffer is full.