Lubricant List
Lubricating location
Applicable oil
Volume
Periodic change
Spray pump crank
case
SAE10W-30
SH class
1.15 liters
Initial: 50 hours
Thereafter: Every 100
hours (*1)
Base of spray
pump cylinder
SAE10W-30
SH class
3 to 5 drops
Every 100 hours (*2)
Input shaft
Molybdenum grease
Appropriate
amount
Once every year
Input shaft
Molybdenum grease
Appropriate
amount
Once every year
Fan transmission
input shaft
Molybdenum grease
Appropriate
amount
Once every year
Fan transmission
GL-5 80W-90
1.3 liters
Initial: 50 hours
Thereafter: Every 600
hours
Bearing unit
Lithium grease
Until grease
protrudes.
Once every year
Drive shaft
Remove cover
Lithium grease
Until grease
protrudes.
Once every year
Drive shaft
Remove undere cover
Lithium grease
Until grease
protrudes.
Once every year
*1: Change at least once a year even before an elapse of 100 hours.
*2: Add oil at least once a year even before an elapse of 100 hours.
Oil filler port