ORDER CODES FOR PIPE ADAPTOR FITTINGS 

RPFS

 

 

Material 

GAL 

PVC 

PVC 

Polypropylene 

Polypropylene  STAINLESS 

BRASS 

BRASS 

Type 

T-Piece 

slip T-piece 

Saddle Clamp 

Saddle Clamp 

Saddle Clamp 

T-Piece 

T-piece 

Socket 

For 

Gal pipe 

Pressure pipe 

Pressure pipe 

Pressure pipe 

Poly Pipe Black 

S/Steel pipe  Brass pipe

 

20   mm 

 

PVC20 

 

 

 

 

BRA20 

 

25   mm 

GAL25 ( -T2) 

PVC25 

 

 

 

SS25 

BRA25 

 

32   mm 

GAL32 

PVC32 

 

 

 

SS32 

 

BSOC: 
1” BSP  

Brass  

pipe socket 

adaptor  

for  

25-100

mm

  

pipes 

also 

BSPB

 & 

BSPSS 

nipple 

adaptor 

40   mm 

GAL40 

PVC40 

PVC40SC 

SCP40 

SC40 

SS40 

 

50   mm 

GAL50 

PVC50 

PVC50SC 

SCP50 

SC50 

SS50 

 

63   mm 

 

 

 

SCPE63 

SC63 

 

 

65   mm 

 

PVC65 

 

SCP65 

SC75 

 

 

75   mm 

 

 

 

 

SC75 

 

 

80   mm 

GAL80 

PVC80 

PVC80SC 

SCP80 

SC90 

 

 

80   mm   GAL80-F 

(Table D flanged)

 

 

 

 

 

 

 

90   mm 

 

 

 

SCPE90 

SC90 

 

 

100 mm 

GAL100 

PVC100 

PVC100SC 

SCP100 

SC114 

 

 

100 mm 

GAL100-F 

(Table D flanged)

 

 

 

 

 

 

 

 

110 mm 

 

 

 

SCPE110 

SC110 

 

 

 

BSOC: 
1” BSP  

Brass  

pipe socket 

adaptor  

for  

100-500  

mm pipes 

also 

BSPB-LS 

Long Stem 

n

ipple 

adaptor

 

125 mm 

 

 

 

SCPE125-LS 

SC125-LS 

 

 

140 mm 

 

 

 

 

SC140-LS 

 

 

150 mm 

 

 

PVC150SC-LS 

SCP150-LS 

SC160-LS 

 

 

160 mm 

 

 

 

SCPE160-LS 

SC160-LS 

 

 

200 mm 

 

 

PVC200SC-LS 

SCP200-LS 

SC200-LS 

 

 

225 mm 

 

 

 

SCPE225-LS 

SC225-LS 

 

 

250 mm 

 

 

 

SCP250-LS 

SC250-LS 

 

 

280 mm 

 

 

 

 

SC280-LS 

 

 

300 mm 

 

 

PVC300SC-LS 

SCPE300-LS 

SC315-LS 

 

 

315 mm 

 

 

 

 

SC315-LS 

 

 

500 mm 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

Galvanised iron   
threaded ends  
BSP (female) 
2000 kPa 
Note: 25mm   
can be supplied  
with straight  
pipe sections  
already fitted  
(Part GAL25-T2) 

PVC 

T-piece 

Class 18 Cat 19 
Glue-in (female) 

1100 kPa 

PVC 

 

1400 kPa 

PVC 

 

 

 

≤ 150mm:  

1600 kPa  

 

> 150mm:  

1000 kPa 

Poly-pipe 

agricultural 

Saddle Clamps 

 

≤ 150mm:  

1600 kPa  

 

> 150mm:  

1000 kPa 

Stainless 

Steel 316  

T-piece.  

 

BSP 

(female) 

threaded 

entry 

 

2000 kPa 

 

Brass  

T-piece  

 
 

BSP 

(female) 

threaded 

entry 

 

2000 kPa 

 

1” BSP  

Brass  

pipe  

socket 

adaptor  

& BSPB 

BSPB-LS  

BSPSS 

nipple 

adaptors 

(see Fig 1 

Page 3)

 

 

 

GAL80 - 80mm Galvanized Iron pipe adapter  

 

 

(80mm ɸ  x  600mm long) 

BSPSS Stainless Steel 

adapter nipple 

for 25-100mm pipes 

BSPB brass 

adapter nipple 

for 25-100mm pipes 

 

 

 

Due to continuous product improvement, specifications are subject to change without notice

.

 

 
 
 
 

** Pipe fitting options for the RPFS are as per the table however other fitting types may also be available on request** 
 
 

 

Содержание ManuFlo ME995-7

Страница 1: ...urrent draw Consider wiring an override button N O with spring return for manual batching or top up of water which will be counted by the controller display See wiring diagram C Install the Rota Pulse paddlewheel sensor RPFS P in a straight pipe section with the same diameter pipe as the adaptor tee section with 10x diameter before and 5x diameter after the sensor with no elbows reducers valves or...

Страница 2: ...1 Litre increments up to a maximum 9000 Litres The controller operates from standard 220 260 vac or optional 24vac 110vac or 12 24 VDC voltage supplies Contact output drive is via one or optional two relays or with OC open contact drive to allow control output switching drive of any external voltage Standard controllers are in panel mount form or optionally can be housed in a metal box or IP65 ABS...

Страница 3: ...ected 200L when 190L on LEDs this is 10L more or 5 over 10 190x100 So decrease the calibration value by 5 i e if calibration set to 300 new value is 300 5 300 15 285 Set Calibration U 5 T 8 H 2 4 If the amount collected is less than is shown on the LED display then increase the set calibration value by the same difference e g if collected 180L when 190L on LEDs this is 10L less or 5 under 10 190x1...

Страница 4: ...wo product changeover output drive Allows 2 flowmeter inputs pump drives e g ME995 7 is the standard Batch Controller 240vac powered whereas ME995 7 MC2 is an ME995 7 Batch Controller with a scaled open collector pulse output and a Start Stop Reset PLC commands interface HOUSING ENCLOSURES SHB SHB1 Single enclosure Powder coated metal Single enclosure Powder coated metal Wired with 240vac contacto...

Страница 5: ... N TWIN SHIELDED CABLE at rear of Batch Controller PUMP ME995 WIRING DIAGRAM ACTIVE Optional batch override top up momentary push button switch Standard AC Wiring for Pump and optional Solenoid at rear of Batch Controller ACTIVE Rear ME995 SHIELD 0 v PULSE SHIELDED CABLE CONTACT CONTACT 1 VDC Optionalbatch override top up momentarypush button switch Gate Valve Solenoid Flowmeter VDC 0v Open Contac...

Страница 6: ...tion to larger size pipes is possible depending on pipe wall thickness alternatively the Long Stem LS versions with adaptors are then used With only one moving part and limited intrusion into the pipe and combined with its flow through design the RPFS allows accurate measurement of liquid flows with virtually no head losses Each of the 4 blades of the rotor paddlewheel extends approximately one ce...

Страница 7: ...val of RPFS from Pipe adaptor Fitting Triangular Keyway Type Nipple Adaptor see FIG 6 1 Unscrew the black PVC locking cap anti clockwise 2 Hold the neck of the Tee piece in your left hand grasp the RPFS body with your right hand and turn slowly anti clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket never by the cable When returning the sensor to nipple...

Страница 8: ...talled in a horizontal inclined or vertical pipe position Note If mounted in horizontal or inclined pipe make sure insertion position of sensor is at top or 45 from top not on the underside Selection of pipe diameter For best results use the table below Pipe size Flowrange Litres min Pulses Litre mm Min Max approx 1 2 20 13 160 116 25 20 250 75 32 30 410 46 40 50 640 30 50 90 1000 20 63 132 1580 1...

Страница 9: ... SC140 LS 150 mm PVC150SC LS SCP150 LS SC160 LS 160 mm SCPE160 LS SC160 LS 200 mm PVC200SC LS SCP200 LS SC200 LS 225 mm SCPE225 LS SC225 LS 250 mm SCP250 LS SC250 LS 280 mm SC280 LS 300 mm PVC300SC LS SCPE300 LS SC315 LS 315 mm SC315 LS 500 mm Galvanised iron threaded ends BSP female 2000 kPa Note 25mm can be supplied with straight pipe sections already fitted Part GAL25 T2 PVC T piece Class 18 Ca...

Страница 10: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 1 ...

Страница 11: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 2 ...

Страница 12: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 3 ...

Страница 13: ... past batch select Faulty solenoid valve not closing service solenoid valve check air pressure or water does not stop properly insufficient air pressure Wet loads more water Paddlewheel bushes worn Check paddlewheel collected than indicated Wheel dirty flowing over range Replace with new paddlewheel recalibrate Dry loads less water Requires recalibration test Set new calibration figure rear switch...

Страница 14: ...c minimum flowrate required If flow drops below 1 5 Litres sec the pulse fail will activate The equation is Pulse fail frequency Hz Pulses Litre x minimum flowrate of pipe diameter in Litres sec The flowrate frequency Hz minimum setting can be adjusted by soldering a capacitor in parallel with the standard capacitor found on the PCB See Table 2 and diagram below for values and location on the PCB ...

Отзывы: