MANU ELECTRONICS

 

PTY LTD

 

Flow Measurement Products

                                                                                            

41 Carter Road, Brookvale NSW 2100 

                                        

                         

 

                                   

Website: 

http://www.manuelectronics.com.au

 

 

RPFS_Datasheet  07/07/2018

 

 

SENSOR CONSTRUCTION 

RPFS

 
 

 Model 

RPFS-P 

RPFS-H 

 

 

 Body 

Delron (Acetal) 

Brass 

 

 

 O-rings x 2 

Neoprene 

Viton 

 

 

 Rotor 

Stainless Steel 17-4PH 

 Bushes 

Delron 

 Axle 

Tungsten Carbide 

 Lockcap 

PVDF 

Brass 

 

 

 Dimensions    
 Overall (approx.) 

130L x 30W mm  150L x 30W mm

 

 

 

 ORDERING CODES:- 

 

 NOTE: All RPFS sensors are supplied with a screw-down LC locking cap 

 

Item 

Description 

 

 RPFS-P 

NPN transistor 5-25VDC sinking pulse,   

liquid temperature to  50

 
 

RPFS-H 

NPN transistor 5-25VDC sinking pulse,   

liquid temperature to 120

 

 

 

SPARE PARTS 
 
PW-N  Spare wheel 
 
PWAH  Axle 
 
PC5      5 mtr m12 lead 
 
LC        Locking Cap 
 
BS020  Orings 
 

 

     

 

 
 

MAINTENANCE 

RPFS

Recommended Periodic Checks: 

With clean liquids, sensor check of the paddle wheel is recommended once every year. In applications with reclaimed or 
contaminated fluids, regular quarterly maintenance checks are recommended.  

 

Removal of RPFS from Pipe adaptor Fitting 

‘Square’

 Keyway Type Nipple Adaptor:

(see FIG 5)

  

1 - Unscrew the black PVC locking cap (anti-clockwise). 
2 - Place a small to medium sized flat thin bladed screwdriver in the join where the insertion sensor body meets the nipple 
     adaptor (See FIG 4), twist the screw driver to prize the two apart till the slots clear the keyways, then pull or twist upwards 
     until the sensor is released (never pull via the cable).  

 

Removal of RPFS from Pipe adaptor Fitting 

‘Triangular’

 Keyway Type Nipple Adaptor:

(see FIG 6)

  

1 - Unscrew the black PVC locking cap (anti-clockwise). 
2 - Hold the neck of the Tee piece in your left hand, grasp the RPFS body with your right hand and turn slowly anti-clockwise until    
     the sensor hydraulically raises out of slot then pull upwards out of the socket (never by the cable).  

 

**When returning the sensor to nipple adaptor insert so the keyway and slots line up then then push down until they locate. Screw 
the black locking cap clockwise to hold the sensor in place (hand tightened only).  

 

Cleaning: 

 

1 - If the paddlewheel (rotor) and or sensor body is coated with scale, immerse the sensor section in diluted hydrochloric acid, scour  
     gently if required. 
2 - 

For ease of removal or refitting of sensor we strongly recommend to lubricate the body O-rings using petroleum jelly.

 

3 - If the paddlewheel requires servicing, push out the axle using a small hole punch or similar implement, remove the  
     paddle wheel and service or replace rotor and/or axle as required (spare parts available from ManuFlo).   

 

 
Fault Diagnosis & Rectification:

 

 If the RPFS sensor ceases to count, the paddlewheel may be blocked, remove inspect and clean as described above. 

 If the RPFS pulses when there is no flow, a nearby 50Hz AC field is probably causing these false counts. Move the flow sensor 

away from the 50Hz field, or move the source of the field if practical. 

 If the standard cable length supplied is not sufficient and needs extending contact ManuFlo for suitable ‘screened’ cable and never 

run extended cable across or near to other cables that are potential EMF sources. 

 

Содержание ManuFlo ME995-7

Страница 1: ...urrent draw Consider wiring an override button N O with spring return for manual batching or top up of water which will be counted by the controller display See wiring diagram C Install the Rota Pulse paddlewheel sensor RPFS P in a straight pipe section with the same diameter pipe as the adaptor tee section with 10x diameter before and 5x diameter after the sensor with no elbows reducers valves or...

Страница 2: ...1 Litre increments up to a maximum 9000 Litres The controller operates from standard 220 260 vac or optional 24vac 110vac or 12 24 VDC voltage supplies Contact output drive is via one or optional two relays or with OC open contact drive to allow control output switching drive of any external voltage Standard controllers are in panel mount form or optionally can be housed in a metal box or IP65 ABS...

Страница 3: ...ected 200L when 190L on LEDs this is 10L more or 5 over 10 190x100 So decrease the calibration value by 5 i e if calibration set to 300 new value is 300 5 300 15 285 Set Calibration U 5 T 8 H 2 4 If the amount collected is less than is shown on the LED display then increase the set calibration value by the same difference e g if collected 180L when 190L on LEDs this is 10L less or 5 under 10 190x1...

Страница 4: ...wo product changeover output drive Allows 2 flowmeter inputs pump drives e g ME995 7 is the standard Batch Controller 240vac powered whereas ME995 7 MC2 is an ME995 7 Batch Controller with a scaled open collector pulse output and a Start Stop Reset PLC commands interface HOUSING ENCLOSURES SHB SHB1 Single enclosure Powder coated metal Single enclosure Powder coated metal Wired with 240vac contacto...

Страница 5: ... N TWIN SHIELDED CABLE at rear of Batch Controller PUMP ME995 WIRING DIAGRAM ACTIVE Optional batch override top up momentary push button switch Standard AC Wiring for Pump and optional Solenoid at rear of Batch Controller ACTIVE Rear ME995 SHIELD 0 v PULSE SHIELDED CABLE CONTACT CONTACT 1 VDC Optionalbatch override top up momentarypush button switch Gate Valve Solenoid Flowmeter VDC 0v Open Contac...

Страница 6: ...tion to larger size pipes is possible depending on pipe wall thickness alternatively the Long Stem LS versions with adaptors are then used With only one moving part and limited intrusion into the pipe and combined with its flow through design the RPFS allows accurate measurement of liquid flows with virtually no head losses Each of the 4 blades of the rotor paddlewheel extends approximately one ce...

Страница 7: ...val of RPFS from Pipe adaptor Fitting Triangular Keyway Type Nipple Adaptor see FIG 6 1 Unscrew the black PVC locking cap anti clockwise 2 Hold the neck of the Tee piece in your left hand grasp the RPFS body with your right hand and turn slowly anti clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket never by the cable When returning the sensor to nipple...

Страница 8: ...talled in a horizontal inclined or vertical pipe position Note If mounted in horizontal or inclined pipe make sure insertion position of sensor is at top or 45 from top not on the underside Selection of pipe diameter For best results use the table below Pipe size Flowrange Litres min Pulses Litre mm Min Max approx 1 2 20 13 160 116 25 20 250 75 32 30 410 46 40 50 640 30 50 90 1000 20 63 132 1580 1...

Страница 9: ... SC140 LS 150 mm PVC150SC LS SCP150 LS SC160 LS 160 mm SCPE160 LS SC160 LS 200 mm PVC200SC LS SCP200 LS SC200 LS 225 mm SCPE225 LS SC225 LS 250 mm SCP250 LS SC250 LS 280 mm SC280 LS 300 mm PVC300SC LS SCPE300 LS SC315 LS 315 mm SC315 LS 500 mm Galvanised iron threaded ends BSP female 2000 kPa Note 25mm can be supplied with straight pipe sections already fitted Part GAL25 T2 PVC T piece Class 18 Ca...

Страница 10: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 1 ...

Страница 11: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 2 ...

Страница 12: ...RPFS and ME995 Wiring and Plumbing Diagrams c 2004 Manu Electronics Pty Ltd 3 ...

Страница 13: ... past batch select Faulty solenoid valve not closing service solenoid valve check air pressure or water does not stop properly insufficient air pressure Wet loads more water Paddlewheel bushes worn Check paddlewheel collected than indicated Wheel dirty flowing over range Replace with new paddlewheel recalibrate Dry loads less water Requires recalibration test Set new calibration figure rear switch...

Страница 14: ...c minimum flowrate required If flow drops below 1 5 Litres sec the pulse fail will activate The equation is Pulse fail frequency Hz Pulses Litre x minimum flowrate of pipe diameter in Litres sec The flowrate frequency Hz minimum setting can be adjusted by soldering a capacitor in parallel with the standard capacitor found on the PCB See Table 2 and diagram below for values and location on the PCB ...

Отзывы: