Mypower
S4100
Troubleshooting
Maipu Confidential & Proprietary Information
Page
57
of
124
802.1AG Troubleshooting
This chapter describes the common problems when using 802.1AG to help
the network administrator analyze and solve the network faults quickly
and improve the production efficiency of enterprises.
Main contents:
z
Basic idea of 802.1AG troubleshooting
z
Common 802.1AG troubleshooting
Basic Idea of 802.AG
Troubleshooting
1.
Check whether the same CFM MD and MA are configured correctly on
the devices.
Checking method: Use the show ethernet cfm domain command to
view whether the MD and MA configured on the devices are consistent.
2.
Check whether ethernet cfm is enabled on the port.
Checking method: Use the show run port/link-aggregation command
to view whether ethernet cfm is enabled on the port. By default, ethernet
cfm is enabled on the port.
3.
Check whether the port belongs to instance vlan.
Checking method: Use the show vlan command to view whether the
ethernet cfm port belongs to the instance vlan.