Energization and Operation
MP1800X Series Router Installation Manual
4-14
copyright
2017Maipu, all rights reserved
Field
Description
flash0: /flash/rp37-7.3.0.58(R).pck
Compiled
Version compile time, such as May 12
2017, 10:24:21
4.3.2
Viewing the System Environment Temperature
The temperature information of the main chips on MP1800X series router may be
viewed by the
show environment
command. For example:
router#show environment
Mpu CPU temperature is 54
°
C
Mpu inlet air temperature is 44
°
C
4.3.3
Viewing the 4G Module Information
The information of the main modules on MP1800X series router may be viewed by the
show fastcellular {n} phyinfo hardware
command. For example: (the print information is
just for reference)
router#show fastcellular 1 phyinfo hardware
Hardware Information
====================
Modem Status = On Line
Modem device name = U8300C
Modem manufacturer = LONGSUNG
Modem Firmware Version = QA30002.1.9_MV11
Hardware Version = PART104_VERSION3.1
SIM Status = EXIST
International Mobile Subscriber Identity (IMSI1) = 460031242852908
International Mobile Subscriber Identity (IMSI2) = 460110504648640
Integrate Circuit Card Identity (ICCID) = 89860315040287598418
International Mobile Equipment Identity (IMEI) = 869751023786526
User Phone Number = None
Modem Functionality Status = online(full functionality)
router#