Installation Preparation 

MP1800X Series Router Installation Manual 

 

2-6 

copyright

2017Maipu,  all  rights  reserved 

 

 

Caution:   

 

Please refer to 

Appendix A Specifications of the Router and Common Modules

” 

for details on the power consumption of the router. 

 

2.2

  Safety Precautions 

2.2.1

  General Safety 

Caution: 

 

The floor of the installation site shall be dry and smooth, with the anti-skid measures 

in place. 

 

The equipment shall be clean, dust free and placed in a dry environment.

 

 

2.2.2

  Electrical Safety 

Caution: 

 

Please carefully check any potential risks within the working area, including power 

ground, grounding reliability and wet ground. 

 

Before installation, it is required to know the location of the emergency power switch 

in the equipment room. In case of an accident, the emergency power switch shall be 

turned off first. 

 

Two or more personnel are preferred to conduct the live maintenance. 

 

When closing the power, check and ensure that the power is turned off.

 

 

2.2.3

  Static Safety 

The anti-static precautions shall be in place to prevent the electronic elements of the 

router from being damaged by the static electricity.

 

Содержание MP1800X-40

Страница 1: ...MP1800X Series Router Installation Manual V1 0...

Страница 2: ......

Страница 3: ...Communication Technologies Co Ltd shall under no circumstance be responsible for any accident negligence breach of contract defamation and infringement of copyright or intellectual property right inc...

Страница 4: ...of energization operation troubleshooting and equipment maintenance Product Version This manual is applicable to the product versions as below Product name Product Version MP1800X series router MP180...

Страница 5: ...ow the specified steps otherwise personal injuries or equipment damages are possible Convention of command formats Format Description Bold Keywords of command line Italic Parameters of command line Br...

Страница 6: ...X Series Router Configuration Manual Detailed introduction to the methods and steps of configuring the equipment software functions with the typical cases made available for reference Technical Suppor...

Страница 7: ...2 2 SAFETY PRECAUTIONS 2 6 2 2 1 GENERAL SAFETY 2 6 2 2 2 ELECTRICAL SAFETY 2 6 2 2 3 STATIC SAFETY 2 6 2 3 INSTALLATION TOOLS INSTRUMENTS AND EQUIPMENT 2 7 2 4 UNPACKING INSPECTION 2 8 3 ROUTER INST...

Страница 8: ...1 1 NO DISPLAY FAILURE TROUBLESHOOTING 5 15 5 1 2 MESSY CODE TROUBLESHOOTING 5 15 5 2 POWER FAILURE TROUBLESHOOTING 5 16 5 3 GAIN TECHNICAL SUPPORTING 5 16 6 ROUTER MAINTENANCE A 1 6 1 DE DUST THE RO...

Страница 9: ...C power supply D 6 D2 2 DC Power Requirement D 7 D2 3 Suggestions on fundamental AC power supply D 8 E Equipment Grounding Specifications and Protection E 1 E1 Equipment grounding specifications E 1 E...

Страница 10: ...DIAGRAM OF THE VERTICAL INSTALLATION 3 2 FIGURE 3 4 THE MINIMUM HEIGHT OF THE TRAY 3 4 FIGURE 3 5 INSTALL THE FLOATING NUTS 3 5 FIGURE 3 6 INSTALL THE ROUTER TO THE 19 INCH STANDARD CABINET 3 6 FIGUR...

Страница 11: ...gures APPENDIX FIGURE A 1 AD24 1S0N POWER ADAPTER A 3 APPENDIX FIGURE C 1 THE DIAGRAM OF THE CONSOLE CABLE C 1 APPENDIX FIGURE C 2 RJ45 BASE C 2 APPENDIX FIGURE C 3 WIFI ANTENNA C 3 APPENDIX FIGURE C...

Страница 12: ...E 4 1 MP1800X 40E INDICATOR DESCRIPTION 4 6 TABLE 4 2 MP1800X 40W INDICATOR DESCRIPTION 4 8 TABLE 4 3 MP1800X 40 SJW12 4G INDICATOR DESCRIPTION 4 9 TABLE 4 4 MP1800X 50 INDICATOR DESCRIPTION 4 11 TABL...

Страница 13: ...AIR C 2 APPENDIX TABLE D 1 REQUIREMENTS FOR ENVIRONMENTAL ADAPTABILITY D 3 APPENDIX TABLE D 2 REQUIREMENTS FOR CONTENT OF DUST IN EQUIPMENT ROOM D 5 APPENDIX TABLE D 3 CONTENT INDEX OF THE HARMFUL GAS...

Страница 14: ......

Страница 15: ...ne USB interface five 10M 100M 1000M Ethernet ports as well as TD LTE FDD LTE TD SCDMA WCDMA EVDO CDMA 1x GSM network The dual SIM card slots can be switched via the DIP switch The device adopts the 1...

Страница 16: ...O CDMA 1x and GSM network and supports WIFI IEEE 802 11b g n The dual SIM card slots can be switched via the DIP switch The device adopts the 12V 24W power adapter to provide power MP1800X 40W dimensi...

Страница 17: ...12V 24W power adapter to provide power MP1800X 40E dimension is 145 x 100 x 38mm W x D x H Figure 1 3 MP1800X 40E appearance 1 SIM card slot 2 Function status indicator 3 Reset button 4 Signal indica...

Страница 18: ...interface 6 Power switch 7 Power socket 8 Grounding screw 1 2 Power Introduction MP1800X 40 MP1800X 40W MP1800X 40E SJW12 4G adopt the external power adapter AD24 1S0N to provide the power The output...

Страница 19: ...ning stroke and interference and satisfy the grounding specifications Refer to Appendix E1 Equipment Grounding Specifications for details Check whether the installation space and handling channel are...

Страница 20: ...environment 2 2 2 Electrical Safety Caution Please carefully check any potential risks within the working area including power ground grounding reliability and wet ground Before installation it is req...

Страница 21: ...ensure that the sheet metal of the ESD wrist well contact with your skin Step 3 Insert the anti static wrist into the anti static wrist jack on the router chassis or clamp the alligator clip of the a...

Страница 22: ...onfigurable terminal a common PC or a laptop Multimeter 2 4 Unpacking Inspection The unpacking steps of MP1800X series router are as follows Step 1 View the carton label and confirm the device model i...

Страница 23: ...nt or vertical surface upright column and other vertical environment Select the correct installation mode according to the actual installation environment 3 1 1 Installing the Router Horizontally Plac...

Страница 24: ...e vertical surface of the wall cabinet and other installation environment by screws Purchase expansion screws or OTC screws according to the installation environment Figure 3 3 The diagram of the vert...

Страница 25: ...escribe the method to install the MP1800X 50 router in a 19 standard cabinet Installation Preparation The height of the MP1800X 50 router is 1U so ensure that the enough installation space is reserved...

Страница 26: ...ed router chassis height and enough margin is reserved 1U margin is recommended Caution To ensure the stability of the cabinet try to place a heavy and high router below the cabinet Step 2 Use the scr...

Страница 27: ...tion Before installing the equipment ensure that the tray has been properly installed to the cabinet which are capable of supporting the equipment and its accessories The steps of installing the route...

Страница 28: ...rews to fix the floating nuts on the chassis mounting ears and cabinet post square hole bar so as to prevent the router from sliding front and back Warning The hanging ear does not bear the weight Do...

Страница 29: ...For the purpose of such configuration the steps below shall be followed Step 1 Prepare a PC or laptop and check whether this PC or laptop has a RS 232 serial port or USB interface Step 2 Connect the...

Страница 30: ...required to firstly disconnect the RJ 45 end and then the DB 9 end 4 1 2 Setting the Hyperterminal Parameters of PC The serial port interface parameter configuration of the PC or laptop is introduced...

Страница 31: ...erface Step 3 Display the following Connection Description interface and fill in the name in Name N such as test and click OK Figure 4 4 Connection description interface Step 4 Display the following C...

Страница 32: ...as 9600 data bit as 8 parity check as none stop bit as 1 and data flow control as none and then click OK Figure 4 6 The COM1 Properties interface Step 6 Display the following test HyperTerminal interf...

Страница 33: ...is complete Figure 4 9 The test Hyperterminal interface after setting 4 1 3 Energization Pre energization Inspection The pre energization inspection for the router includes The interface cable power c...

Страница 34: ...M NAND 512 MiB PCI arm_clk 1000MHz axi_clk 500MHz apb_clk 250MHz arm_periph_clk 500MHz Net bcmiproc_eth 0 Press ctrl c to enter bootloader mode 0 Use boot parameter 0 device flash0 file rp37 7 3 0 58...

Страница 35: ...4G channel 1 has no data receiving and sending or works abnormally 4G indicator 2 SIM2 Monochrome green light On The SIM card of 4G channel 2 is in place Off The SIM card of 4G channel 2 is not in pl...

Страница 36: ...tus System status indicator SYS green Flash quickly 5Hz flash frequency The hardware starts to work after energization Flash slowly 0 5Hz flash frequency The system works normally On off The system wo...

Страница 37: ...l port has no data receiving GET interface status indicator 1000M Yellow On The Ethernet port is connected successfully and the negotiated rate is 1000M Off The Ethernet port is not connected or is co...

Страница 38: ...light On The SIM card of 4G channel 2 is in place Off The SIM card of 4G channel 2 is not in place or the module is abnormal 4G signal indicator Signal strength Monochrome green light All on The sign...

Страница 39: ...flash frequency The hardware starts to work after energization Flash slowly 0 5Hz flash frequency The system works normally On off The system works abnormally Power status indicator PWR green On The...

Страница 40: ...00Base T uses the RJ 45 connector with MDI MIDX self adaption supported The network is accessed by the twisted pair of Category 5 or above The connection steps are Step 1 Insert an end of the Ethernet...

Страница 41: ...ight C 2014 Maipu Communication Technology Co Ltd All Rights Reserved MP1800X 40E V1 Version Information System ID 00017a205314 Hardware Model MP1800X 40E V1 with 512 MBytes SDRAM 128 MBytes flash Har...

Страница 42: ...rmation of the main modules on MP1800X series router may be viewed by the show fastcellular n phyinfo hardware command For example the print information is just for reference router show fastcellular...

Страница 43: ...guration cable is connected to Console port If no problem is found in the above checks there may be the following reasons 1 The serial port connected to the configuration cable is wrong the actual sel...

Страница 44: ...ble is damaged If no contact the agent or the local technical engineer 5 3 Gain Technical Supporting In case the failure still exists after implementing the above steps you are requested to contact th...

Страница 45: ...lation in the router dissipation the board will inevitably absorb and accumulate the charged particle or dust in the air When the air cleanliness is weaker and the relative humidity is lower this abso...

Страница 46: ...ticles attached on the surface of the board This method is characterized with difficult operation and high cost Appendix A Specifications of the Router and Common Modules A1 Dimension Weight Power Con...

Страница 47: ...G routers adopt the DC power supply which is converted to the DC power via the external power adapter The power adapter has the following specification Specification Description AD24 1S0N Power adapte...

Страница 48: ...port properties Property Description Interface standards Asynchronous EIA TIA 232 Connector type RJ45 Rate 2400bps 4800 9600 19200 38400 57600 115200bps The default value 9600bps Supported services C...

Страница 49: ...ction cable Twisted pair of Category 5 or above B3 Properties of USB Interface Appendix Table B 3 USB interface properties Property Description Interface standard USB2 0 Interface type USB A Work mode...

Страница 50: ......

Страница 51: ...the console cable of the MP1800X series router is an eight core unshielded cable The one side of the cable is the crimping RJ 45 crystal plug and the other side is a DB9 hole The view of the console...

Страница 52: ...e 8 core straight through unshielded twisted pair of category 5 or above Appendix Table C 2 The connection relation of the RJ45 cable category 5 twisted pair RJ45 Signal Direction RJ45 Description Len...

Страница 53: ...blocks shall be tightly and solidly laid with horizontal error of each square meter of no more than 2mm When raised floor is unavailable the static conducting flooring volume resistivity shall be 1 0...

Страница 54: ...hange and metal part corrosion etc Long term too low humidity in the equipment room will cause the insulating spacer to shrink leading to looseness of the fastening screw also the dry climatic environ...

Страница 55: ...shown in the following table Appendix Table D 2 Requirements for content of dust in equipment room Maximum diameter m 0 5 1 3 5 Maximum concentration particle m3 1 4 107 7 105 2 4 105 1 3 105 Caution...

Страница 56: ...t away from high power radio transmitting station radar station and high frequency high current equipment Users can conduct anti interference through electromagnetic shielding method if necessary D1 5...

Страница 57: ...D 4 Requirement for fundamental AC power supply Item Index Input voltage range 100 240V Input frequency range 50 60Hz Caution The AC conducting wires shall be flame retardant and routed as specified...

Страница 58: ...upply Suggestions on fundamental AC power supply include If the equipment is directly powered by mains supply and its power supply voltage exceeds 10 5 of the rated voltage or the voltage range allowe...

Страница 59: ...rounding share a group of ground body 2 Protection ground shall be done for the cable tray hung iron stand rack or casing metal ventilating duct and metal door and window etc in the equipment room 3 P...

Страница 60: ...ns of various metal parts of the cabinet are prohibited from spraying insulation paint 5 The rack bodies of cabinets on the same row shall be closely connected with each other through the fastening bo...

Страница 61: ...he same room 7 The DC power shall be added the protection circuit against surge E1 5 Specifications for ground cable laying The ground cable laying specification is as shown in the following table App...

Страница 62: ...category and bundling of cables of different categories shall be avoided It is suggested that cables are bundled with one cable tie every other 100mm to strengthen the management and fixation Ground...

Страница 63: ...side the enclosure and the power cable shall be kept a distance of above 20cm from other cables Cable installation method Signal cables shall be installed and bundled by category according to indoor a...

Страница 64: ...PBB Polybrominat ed diphenyl ether PBDE Printed wiring board components2 O O O O O Switch mode power supply O O O Casing subra ck metal O O O O O O Enclosure base plate O O O O Screw O O O O Dust pro...

Страница 65: ...t is 5 years and that of other parts is 50 years See the requirements for operating environment in the product manual for the product use conditions in the environment friendly use period Note Note 1...