9 Functions of additional circuit board 1 | UK
89
As an
installer
: Enter user name
service
and password
6940
. The web server
opens.
i
You can now access your ventilation
unit from any PC in your network via
http://maicokwl
.
5. Undertake commissioning.
6. Remove connecting cable. Fit front cover
and front plate.
8.9 Operation via app / web tool
310/410
320/470
170
160 Flat
300 Flat
Trio
1. Connect as described in Chapter 8.8,
steps 1 to 4. In step 2, under
Settings/
Internet
in the web server also set
air@
home
parameter to
yes
.
2. Call up
web tool
(www.air-home.de)
or
app
.
3. Log in with the access details emailed to
you during registration.
8.10 RESET
310/410
320/470
170
160 Flat
300 Flat
Trio
i
Unit settings are permanently lost
during a reset. Back up the data with
the commissioning software before
resetting.
The unit settings can be reset with the two
reset functions
Chapter 6.2.
Resetting customer & installer level
Complete reset, all unit parameters are reset
to the factory settings.
Resetting customer level
The owners and tenant settings are deleted.
The settings undertaken in the installer menu
are retained.
9 Functions of additional circuit
board 1
310/410
320/470
170
160 Flat
300 Flat
There are 3 slots (170 units: 2 slots) for
optional additional circuit boards (ZP1 or ZP2)
on the control console. Any combination of
circuit boards is possible. Installation is as
described in the accessories instructions.
DIP switch setting options (only 1 function
can be set)
Brine earth heat exchanger, zone ventilation,
3-way air shutter or supplementary heating.
9.1 Brine earth heat exchanger control
The outside air can be heated in the winter
and cooled in the summer with a brine earth
heat exchanger.
No extra temperature sensor is needed to
control the brine circulating pump (controlled
or uncontrolled brine CP). This is handled by
the air inlet temperature sensor in the ventila-
tion unit.
If heating, the brine CP is controlled using
the unit-specific frost protection strategy
Chapter 8.4. For more information
Chapter 6.8.
9.2 Zone ventilation
Zone ventilation setting
Chapter 6.9.
Units with zone ventilation can feed different
amounts of the volumetric air flow provided
into 2 room zones. For example, into zone 1
(living areas) and zone 2 (bedrooms).
● The volumetric flow of one zone can be
reduced by up to 60 %.
●
Zone ventilation is only active in the nominal
ventilation level. It is deactivated in the other
ventilation levels or if the bypass is open.
Zones 1 and 2
are set
in
Auto Time
operating
mode using a time programme. 4 time seg-
ments can be saved per day with supply air
volumes defined for zones 1 and 2
Chap-
ter 6.4.