Maintenance Manual
MAN-00
135
GENIO DC
(BS-III & BS-IV)
JULY 2011
/Rev1
The repair methods given by the manufacturer in this document are based on the technical specifications
,
current at the time of release. The methods may be modified as a result of changes
introduced by the manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of
or
whole of the present document, are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the
Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution
© 2011 Mahindra & Mahindra Ltd.
52
705-MAT-0038 : 0.40 hrs
BODY MOUNTING BOLTS - TIGHTEN
Park the vehicle in inspection pit /2 post lift/ 4 post lift.
If the activity is done on a 2 post lift, ensure that the LSPV spring is
disconnected before lifting the vehicle. After lowering, re-connect the LSPV
spring and ensure that the setting height is correct.
Nut/ Bolt description
Spanner Size
Quantity Nos.
Torque Value – Nm.
•
Cabin/ Cargo mtg. bolts
13 mm.
06/ 10 nos.
65 ± 05 Nm.
NOTE:
(Refer above sketch for body mount location)
Locations mentioned in above chassis frame layout
LH/RH 1 to LH/RH3
are cabin body
mounts; Whereas
LH/RH 4 to LH/RH 6
are cargo box mounts.
In Genio DC, Cabin mounts/ triggers on front both LH/RH are different than rest two.
Front mounts LH & RH are smaller in size/ Dia. than LH/RH2 & LH/RH3.
GENIO – Chassis Frame layout
...
Cabin Mounts
Cargo Mounts