
Wiring an SDI-12 Master card
After installing the card, connect it to the SDI-12 sensor using either of the two 3-way terminal blocks. Two
terminal blocks are provided for user convenience when wiring multiple sensors.
The “
Transparent Mode
” port allows you to send extended SDI-12 commands to sensors using a terminal
program such as Microsoft
®
HyperTerminal
®
.
Connect the PC running the terminal program using a serial cable (or USB-to-serial adapter).
The port settings in the terminal program should be set to the following:
l
9600 baud
l
8 data bits
l
No parity
l
1 stop bit
l
No flow control
NOTE: When a transparent mode session is in progress the LED Transparent Mode
Indicator will light.
HyperTerminal is a registered trademark of Microsoft Corporation in the United States and other countries.
MACE XCi User Manual - 99 -
Содержание HydroMace XCi
Страница 1: ......
Страница 13: ...MACE XCi User Manual 13...
Страница 19: ...MACE XCi User Manual 19...
Страница 33: ...MACE XCi User Manual 33...
Страница 36: ...MACE XCi User Manual 36...
Страница 167: ...NOTE None of these parameters can be edited MACE XCi User Manual 167...
Страница 182: ...MACE XCi User Manual 182...
Страница 187: ...MACE XCi User Manual 187...
Страница 200: ...NOTE In the example the Net flowrate will be the sum of Flow Rate 1 Flow Rate 2 Flow Rate 3 MACE XCi User Manual 200...
Страница 260: ...5 Tighten all three screws 6 Reconnect the battery cable assembly to the backplane board MACE XCi User Manual 260...
Страница 265: ...MACE XCi User Manual 265...