Introduction to XCi channel types
The MACE XCi system uses "
Channels
to enable various measurements to be made and other parameters
- The essential steps to configuring an HydroMACE XCi device
). These
"
Channel types
" can be defined as:
Connected sensor channels -
These channels output their value based on information received from
physically connected sensors wired
to the various MACE FloSeries3 Cards.
Calculated channels -
These channels use the values received from "
Connected sensor channels
" and apply algorithms in order
to output calculated values. For example, when calculating a flow rate in a partially full pipe a "
Flow rate
(using velocity
)" channel type uses the values received from a
connected velocity sensor and a connected
depth sensor
System channels -
These channels have values directly received from the XCi system.
Full list of XCi channel types and brief description:
XCi Channel Types
Description
Velocity
This channel type MUST be used whenever the resultant velocity
measurement will be used in a flow rate calculation. It MUST be
used whenever a MACE Doppler ultrasonic sensor is used to meas-
ure velocity.
Depth
This channel type MUST be used whenever the resultant depth
measurement will be used in a flow rate calculation. It MUST be
used whenever a MACE Doppler ultrasonic sensor is used to meas-
ure depth.
Velocity (depth corrected)
Used to apply a correction factor to measured velocity data based
upon different depth regimes of the stream.
Flowrate (using velocity)
Used to calculate a flow rate based upon the results obtained from
configured velocity and depth channels.
Flowrate (using trickle flow)
This channel uses the Mannings formula to calculate flow rate in a
circular pipe based upon depth measurement.
MACE XCi User Manual - 145 -
Содержание HydroMace XCi
Страница 1: ......
Страница 13: ...MACE XCi User Manual 13...
Страница 19: ...MACE XCi User Manual 19...
Страница 33: ...MACE XCi User Manual 33...
Страница 36: ...MACE XCi User Manual 36...
Страница 167: ...NOTE None of these parameters can be edited MACE XCi User Manual 167...
Страница 182: ...MACE XCi User Manual 182...
Страница 187: ...MACE XCi User Manual 187...
Страница 200: ...NOTE In the example the Net flowrate will be the sum of Flow Rate 1 Flow Rate 2 Flow Rate 3 MACE XCi User Manual 200...
Страница 260: ...5 Tighten all three screws 6 Reconnect the battery cable assembly to the backplane board MACE XCi User Manual 260...
Страница 265: ...MACE XCi User Manual 265...