3.13
Connecting Batteries
The procedure for connecting batteries differs depending on the windrower model. Refer to
Batteries on an M205 or M155, page 72
or
3.13.2 Connecting Batteries on an M105, page 73
3.13.1
Connecting Batteries on an M205 or M155
DANGER
To avoid bodily injury or death from unexpected startup of the machine, always stop the engine and remove
the key from the ignition before leaving the operator’s seat for any reason.
1.
Stop engine and remove key from ignition.
2.
Open the right-hand (cab-forward) maintenance platform.
3.
Ensure the battery main disconnect switch (A) is
turned to the POWER OFF position (the battery main
disconnect switch is located on the right-hand frame
rail beside the batteries).
4.
Remove the cable ties securing the battery cables to
the battery clamps.
IMPORTANT:
Batteries are negative grounded
. Always
connect red starter cables to the positive (+)
terminals of the batteries and black ground
cables to the negative (-) terminals of the
batteries. Reversed polarity in the batteries or
alternator may result in permanent damage to
the electrical system.
Figure 3.108: Battery Main Disconnect Switch
147962
72
Revision A
Содержание M Series
Страница 2: ...Featuring the Dual Direction and Ultra Glide suspension on the M155 and M205 Published in August 2016 ...
Страница 5: ...Figure 2 EC Declaration of Conformity Windrower Lift Sling Page 2 of 2 147962 iii Revision A ...
Страница 7: ...Figure 4 EC Declaration of Conformity Windrower Assembly Supports Page 2 of 2 147962 v Revision A ...
Страница 10: ......
Страница 20: ......
Страница 33: ...UNLOADING THE WINDROWER 9 Unhook the remaining sling Figure 2 24 Platforms 147962 19 Revision A ...
Страница 40: ......
Страница 166: ......
Страница 332: ......
Страница 395: ......