MAC215986
105
Revision A
Auger Flighting
The auger flighting on the FM200 can be configured for particular harvesting and crop conditions.
For instructions, refer to
3.8.1 FM200 Feed Auger Configurations, page 89
for combine/crop specific configurations.
Removing Bolt-On Flighting
The feed auger has removable flighting that can be customized to the different models of combines.
Before removing the bolt-on flighting, determine the quantity and type of flighting required. For information on the
different flighting configurations, refer to
3.8.1 FM200 Feed Auger Configurations, page 89
To remove bolt-on flighting, follow these steps:
1.
To improve access to the feed auger, remove the float module from the combine.
B
1033992
A
Figure 3.109: Auger Access Cover
–
Right Side
2.
Rotate the auger as needed.
NOTE:
The illustrations in this procedure show the feed auger
separated from the float module for clarity. The procedure
can be performed with the feed auger installed in the float
module.
3.
Remove bolts (A) and access cover (B). Retain these parts
for reassembly. If necessary, remove multiple access covers.
B
B
1035933
A
B
C
Figure 3.110: Short Flighting
–
Right Side
4.
Remove bolts and nuts (B) and remove flighting (A).