background image

© 2017 MA Lighting Technology GmbH | Dachdeckerstr. 16 | D-97297 Waldbüttelbrunn | Germany

Phone +49 5251 688865-30 | tech.support (at) malighting.com | www.malighting.com

Version 3.3

1

Hint:

A port is never destination and source at the same time. 

 

7.12.  Upload Switch Configuration

You can upload a previous exported switch configuration, or parts of switch configuration.
This is useful if you have to configure several switches with the same configuration.

Figure 1: Switch Configuration

Important:

The configuration file uploaded via the onPC does not affect the IP address. The configuration file
uploaded via the web interface, however, does affect the IP address. 

Important:

The configuration file has to be written in a JSON (JavaScript Object Notation) data format. If it is not in
a JSON data format, the switch can not read the configuration file.

Hint:

If you are not sure how to write the configuration file, 

get the current switch configuration

 and modify

this file.

60

Содержание Network Switch

Страница 1: ...Version 3 3 2017 04 24 English...

Страница 2: ...able of contents Introduction Intended Use Dangers caused by Electric Current General Safety Instructions System Requirements SFP Transceiver Compatibility Device Overview Front Panel Rear Panel LED I...

Страница 3: ...54 7 9 54 7 10 56 7 11 57 7 12 58 7 13 61 8 62 9 65 10 66 11 68 Presets Filters Assign Presets to Ports Apply Filters to Ports Create New Presets Update Presets Create New Filter View Filter Data Del...

Страница 4: ...es a local display for port status applied filters and recognized MA equipment Additionally it shows workload status of the switch and every single port for easier fault finding The MA network switch...

Страница 5: ...k Schematic 1 1 Intended Use The MA Network Switch is intended to be operational right out of the box as a standard switch In the default configuration it will forward packets between connecting devic...

Страница 6: ...e the device to rain or moisture Do not dive the device in water 1 3 General Safety Instructions Follow the safety instructions to avoid physical injury or material damage Do not grab inside the devic...

Страница 7: ...port at malighting com www malighting com Version 3 3 1 5 SFP Transceiver Compatibility The following SFPs transceivers are tested and compatible with the MA Network Switch Cisco MGBT1 Gigabit 1000 Ba...

Страница 8: ...ech support at malighting com www malighting com Version 3 3 2 Device Overview The following chapter gives you an overview about the device of the MA Network Switch 2 1 Front Panel 13 x Link LEDs 13 x...

Страница 9: ...x Optical Fiber Connectors optional 2 x Optical Fiber Link LEDs 2 x Optical Fiber Group LEDs 1 x USB2 Type B connector 2 x SFP cage for Mini Gbic complaint transceiver external 2 x SFP cage for Mini G...

Страница 10: ...ach indicator Power LED Status Meaning Off No power Green Power supply OK Red blink Error Status LED Status Meaning Green All OK Green blink Update Red Error Link LED Status Meaning Off No link Green...

Страница 11: ...set IP address to the default IP address displayed at the front end display The default IP address is always the factory given IP address per device Reset subnet mask to 255 255 255 0 Reset default ga...

Страница 12: ...y default Art Net Preset MA Remote The preset MA Remote contains the following filters by default HTTPS dport 443 HTTPS sport 443 HTTP dport 80 HTTP sport 80 MA Webremote dport 8080 MA Webremote sport...

Страница 13: ...MA Webremote dport 8080 MA Webremote sport 8080 MA Remote 7003 MA Remote 7002 MA Remote 7001 Telnet dport 30000 Telnet sport 30000 Telnet dport 23 Telnet sport 23 nmbd tcp nmbd udp SMB tcp 139 SMB ud...

Страница 14: ...010 dot2 Net data IPv6 IPv6 UDP dport 30011 MIDI Show Control IPv4 UDP dport range 6000 6020 MA Net IPv4 UPD dport 9138 VPUremote dport 7005 TCP dport 7005 VPUremote sport 7005 TCP sport 7005 VPUremot...

Страница 15: ...db ttelbrunn Germany Phone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 NFS tcp TCP dport 111 NFS udp UDP dport 2049 FTP TCP dport 21 CITP MA TCP dport 30002 CITP UD...

Страница 16: ...9 and 10 Two are inside the MA Switch To install mini GBIC transceivers inside the switch at port 11 and port 12 call your local distributor Install mini GBIC at port 9 and 10 1 Remove the mini GBIC f...

Страница 17: ...on with a PC 1 Plug in the power cable into the switch The switch starts booting 2 Plug in a network cable into one of the Ethernet ports of the switch For the PC connection and for further configurat...

Страница 18: ...2 Go to the Control Panel on the computer 3 Go to Network and Sharing Center and click on Change adapter settings 4 Right click the connection for your LAN and then click Properties If you re prompte...

Страница 19: ...en the MA Switch and a computer indicated by a green or an orange blinking link LED 1 Open the web browser 2 Type the switch IP address in the address bar Hint The IP address is displayed in the front...

Страница 20: ...hU s e r Ma n u a l 2017 MA Lighting Technology GmbH Dachdeckerstr 16 D 97297 Waldb ttelbrunn Germany Phone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 MA Network...

Страница 21: ...e after booting the MA Network Switch Figure Groups View The groups view displays the assigned group of each port in the group color The title bar displays the assigned switch name and the IP address...

Страница 22: ...o open the name view on the display of the MA Network Switch press the yellow menu button Name View The title bar displays the name of the switch and its IP address The column on the left of the displ...

Страница 23: ...tle bar is the switch load and the network load in percent The switch load displays how much the CPUof the switch is used at the moment A high percentage means that the web interface or processes that...

Страница 24: ...tle bar displays Link Aggregation and the IP address of the MA Network Switch The column on the left and right is displayed in the same manner as in the Name View The version of the MA Network Switch...

Страница 25: ...out what is connected to what port you can change the port description of each port Change Port Description The port description has a maximum length of 8 characters The following characters are allow...

Страница 26: ...h 13 can be manually configured at the Edit Ports Groups Window By default all groups are managed groups The assigned group has a green dot The switch has eight different groups 1 Group01 Red 2 Group0...

Страница 27: ...g tree If there are more than one point to point connections between two switches RSTP manages the redundant link unless the original connection fails Important The MA Network Switch supports an imple...

Страница 28: ...ou have more than one connection between two devices then RSTP is required If you then disable RSTP there is no connection 5 4 Edit Speed Setting You can edit the port speed of each port on the MA Net...

Страница 29: ...a better overview every group name is displayed in a different color Important The group name is a label for better overview and does not affect the VLAN Edit Ports Groups Group Names Requirement Conn...

Страница 30: ...ackets and forward them to the registered ports IGMP snooping is disabled by default Hint To forward only known multicast network packets enable IGMP Snooping and IGMP Querier Disable unknown flooding...

Страница 31: ...e multicast packets to the corresponding ports If more than one querier is activated per group the switch with the lowest IP address will be elected as querier This election process is automated IGMP...

Страница 32: ...every port Unknown flooding can be global enabled or disabled for all groups By default unknown flooding is enabled Yes All unknown packages will be forwarded No All unknown packages will be dropped H...

Страница 33: ...o 4095 Group Default VLANID 1 100 2 200 3 300 4 400 5 500 6 600 Important If you change the VLANID of a group you need to change the VLANID of each switch using this group The VLANIDs of the groups wh...

Страница 34: ...atching the filters of this preset will be blocked If a preset is set to block red the network packets matching the filters in the presets are blocked All other network packets not matching the filter...

Страница 35: ...e For more information about the predefined filters see factory defaults If you are a network configuration expert you can create new presets and new filters For more information see create new preset...

Страница 36: ...ck the protocol in a port click a preset once The status is displayed by a red dot To allow the protocol in a port click a preset twice The status is displayed by a green dot 3 Click Apply settings an...

Страница 37: ...Edit Presets 2 Scroll down to the end of the page and click in the bottom right corner Extended filter and preset config Figure 1 Access Extended Mode The extended mode opens Figure 2 Extended Mode In...

Страница 38: ...ngs and stay where you are or Apply settings and leave edit The selected filters are applied and saved in the startup configuration A filter icon is visible right beside the group name on the front di...

Страница 39: ...at the end of the filter list Save as preset Figure 1 Extended Mode Save as Preset 2 The save presets pop up opens Figure 2 Save Presets 3 Enter a name for the new preset e g Telnet All 4 Click Create...

Страница 40: ...ter assignment for the preset in the assigned port column 3 Click Save as preset at the end of the port column The save presets pop up opens Figure Update Preset 4 Select in the drop down the preset y...

Страница 41: ...ww malighting com Version 3 3 Open Edit Filters pop up Requirement Connection to the Web Interface 1 Click Edit Presets 2 Click at the bottom right corner Extended filter and preset config 3 Click at...

Страница 42: ...tion Create IPv4 UDP Filter or IPv4 TCP Filter Information The mask is used to determine the range of the IP destination Example 1 IP destination 192 168 1 129 IPv4 mask 255 255 255 255 All packets se...

Страница 43: ...icast Multicast Broadcast 5 Select the DPort type destination port type Choose between Single Port or Port Range 6 Enter the DPort destination port number Valid port numbers are between 0 65535 7 Clic...

Страница 44: ...u are using new lines the configuration can not be applied Requirement Open edit filters pop up 1 Paste the configuration data into the field 2 Click Create filter The filter is created and visible at...

Страница 45: ...hone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 3 Scroll down to the end of the page and click Custom filters The Edit filters pop up opens Figure 1 Edit Filters p...

Страница 46: ...r Ma n u a l 2017 MA Lighting Technology GmbH Dachdeckerstr 16 D 97297 Waldb ttelbrunn Germany Phone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 Figure 2 View Filt...

Страница 47: ...nt Connection to the Web Interface 1 Click Edit Presets 2 Click in the bottom right corner Extended filter and preset config Figure 1 Access Extended Mode The extended mode opens 3 Click in the bottom...

Страница 48: ...ters Warning After you delete a customized filter you can not restore them The predefined filters can be restored by a factory reset Requirement Connection to the Web Interface 1 Click Edit Presets 2...

Страница 49: ...30 tech support at malighting com www malighting com Version 3 3 5 Click Delete filter A warning asks if you really want to delete this filter Information If the filter you tried to delete is contain...

Страница 50: ...49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 7 General Settings To access the general settings click Tools Edit General Settings in the lower left corner of the over...

Страница 51: ...n to the web interface 1 Click Tools Edit General Settings 2 Enter the new name e g Stage Left 3 Click Apply settings and stay where you are or Apply settings and leave edit The new name is applied an...

Страница 52: ...e IP address of the MA Network Switch The IP address will be used to reach the web interface The current IP address is displayed at the upper right corner of the front display and in the title bar of...

Страница 53: ...rface 1 Click Tools Edit General Settings 2 Type the subnet mask in the subnet mask field 3 Click Apply settings and stay where you are or Apply settings and leave edit The new subnet mask is applied...

Страница 54: ...z Numbers 0 9 Spaces minus plus underscore _ Requirement Connection to the web interface 1 Click Tools Edit General Settings 2 Click Change password 3 Type the old password type the new password type...

Страница 55: ...ch display and in the web interface Download the latest version of the switch on www malighting com Requirement Connection to the web interface 1 Download the latest firmware on www malighting com and...

Страница 56: ...9 5251 688865 30 tech support at malighting com www malighting com Version 3 3 interface We recommend that the switches always run the same firmware in the same network Requirement Connection to the w...

Страница 57: ...hdeckerstr 16 D 97297 Waldb ttelbrunn Germany Phone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 Downdating to older firmware 4 Click OK The MA Network Switch starts...

Страница 58: ...the web interface 1 Click Tools Edit General Settings 2 Click Switch configuration 3 Click Get the current switch configuration A browser window opens 4 Click Save File and OK Depending on the browser...

Страница 59: ...le destination port at a time Use the Web Interface Requirement Connection to the web interface 1 Click Tools Edit General Settings 2 Click Edit Port Mirroring 3 The editor opens Edit port mirroring 4...

Страница 60: ...n This is useful if you have to configure several switches with the same configuration Figure 1 Switch Configuration Important The configuration file uploaded via the onPC does not affect the IP addre...

Страница 61: ...cluded in the configuration file If parts are missing in the configuration file the configuration upload does not work Requirement Connection to the web interface 1 Click Tools Edit General Settings 2...

Страница 62: ...st of all settings and information they are reset Resetting the MA Switch is not reversible After a reset all previous settings are lost and cannot be recovered Use the Web Interface Requirement Conne...

Страница 63: ...ork Switch Power 1 x Neutrik powerCONIn Switch Features RSTP Yes Groups VLANs Yes Fan 2 Ethernet Compliance IEEE 802 3 IEEE 802 3u IEEE 8023x Flow Control IEEE 802 3ab Gigabit Ethernet Supported Proto...

Страница 64: ...ble Auto Sensing Full or Half Duplex Gigabit is Full Duplex Status Reports Front End Display Yes Ethernet Port Connection Link Group Ethernet Port Speed 100 1000Mbps LED Device Status LED Green Red Po...

Страница 65: ...30 tech support at malighting com www malighting com Version 3 3 Physical Enclosure Metal housing Dimensions W x D x H 483 x 233 x 43 mm 19 x 9 17 x 1 69 Weight without optical fiber connector 3 5 kg...

Страница 66: ...A system or specifics of networks in the lighting world see the MA System Specialist Training Technical Service and Support MA Lighting and its extensive distributor network offer an unparalleled tech...

Страница 67: ...ameters automatically from a DHCP server reducing the need for a network administrator or a user to configure these settings manually E Ethernet Is a local network with bus topology what allows multip...

Страница 68: ...t the rear panel and two inside of the MA Network Switch R RSTP Rapid Spanning Tree Protocol Provides significantly faster spanning tree convergence after a topology change introducing new convergence...

Страница 69: ...1 4 Change Default Gateway 7 6 Change DHCP Client 7 3 Change Group Name 5 5 Change ID 7 2 Change IP Address 7 4 Change Name 7 1 Change Password 7 7 Change Port Description 5 1 Change Speed 5 4 Change...

Страница 70: ...c Current 1 2 Environmental 8 Factory Defaults 2 4 Fallback to Backup Firmware 7 9 Filter 6 2 6 5 Filter Configuration 6 5 Filter Defaults 2 4 Filter Icon 4 1 Filters 6 6 2 First Steps 3 Front Panel 2...

Страница 71: ...agement 8 mini GBIC 3 2 mirror ports 7 11 Modify Presets 6 4 name 4 2 Name 7 1 Name view 4 2 Network Cable 3 4 Network Load 4 3 Network Traffic 4 3 New Presets 6 3 Online Help 9 Out 4 3 Password 7 7 P...

Страница 72: ...abled 5 3 RSTP Enabled 5 3 Safety 1 3 Save Preset 6 3 Save Switch Configuration 7 10 Set the IP Address on the PC 3 5 SFP 3 2 SFP Module 1 5 SFP Transceiver Compatibility 1 5 Speed Configuration 5 4 S...

Страница 73: ...Technology GmbH Dachdeckerstr 16 D 97297 Waldb ttelbrunn Germany Phone 49 5251 688865 30 tech support at malighting com www malighting com Version 3 3 VLAN5 9 VLANID 5 9 Web Interface 3 6 What are Fil...