3.3. Installation in a Rack
The MA Network Switch is 1U high and will fit in most standard 19-inch racks.
1. Insert the switch into the 19-inch rack and secure with suitable screws.
Ensure the ventilation holes are not obstructed.
2. Connect the switch to the power supply.
3. Connect the cables.
The MA Network Switch is installed in a rack.
3.4. Connect the Hardware
Requirement:
Shielded twisted pair cable with RJ45 connector, min. Cat 5e
- or -
etherCON cable with Neutrik etherCON connector.
Connection with a PC
1. Plug in the power cable into the switch.
The switch starts booting.
2. Plug in a network cable into one of the Ethernet ports of the switch.
For the PC connection and for further configuration, you have to use a manage group port. We recommend
port 13 at the front.
3. Plug in the other end of the network cable into the Ethernet port on the PC.
A green or orange link LED on the switch indicates a successful connection.
The MA Network Switch is connected with the PC.
Connection with a grandMA2
1. Plug in the power cable into the switch.
The switch starts booting.
2. Plug in a network cable into one of the Ethernet ports of the switch.
3. Plug in the other end of the network cable into the Ethernet port 1 of the grandMA2 console.
A green or orange link LED on the switch indicates a successful connection.
The MA Network Switch is connected with the grandMA2.
3.5. Set the IP Address on the PC