Application Note #480
14
www.lutron.com
Programming Option 5: Enable / Disable Indicator Lights
What Does It Do:
When the sensor dimmer is turned OFF and the light goes out, the Indicator Lights remain ON, at a dim glow state, also
known as "nightlight mode." Disabling "nightlight mode" is an energy saving practice and also allows the dimmer to be
compatible with a broader range of CFLs and LEDs. Enabling "nightlight mode" provides a soft glow for easy location of
the dimmer
in a dark room.
SETTINGS
Enable / Disable Indicator Lights allows for enabling / disabling of the Indicator Lights when the dimmer is turned OFF.
Note:
Default setting is Indicator Lights (nightlight mode): ON (IL4).
DIRECTIONS
Enable / Disable Indicator Lights
1. While in Advanced Programming Mode (APM),
Press the
Raise / Lower
button to select the fifth option,
Programming Option 5: Enable / Disable Indicator Lights.
Once Indicator Light
(IL5) is blinking, Press the Tap
button. The IL will then switch to the current setting and
begin blinking rapidly or turn OFF
, indicating that the
programming option has been entered.
2. Upon entering the Enable / Disable Indicator Lights programming option by
Pressing the Tap
button and observing
the IL changing to a
fast blink on IL4 or turning OFF
,
Press the Raise / Lower
buttons to enable / disable the
nightlight mode (ON / OFF.)
Note:
When pressing any other option other than IL4, all other Indicator Lights will remain OFF. This represents the
Disabled Setting.
3.
To Save
the desired Enable / Disable Indicator Lights setting,
Press the Tap
button. This will exit out of the
Enable / Disable Indicator Lights option and return to APM main menu.
Or
R
L
IL4:
Indicator
Light is "ON"
fast blinking)
(default)
Note:
• It may be necessary to disable the Indicator Lights (nightlight mode) when using certain CFL and LED bulbs to
achieve best bulb performance.
• If there is no button activity for 1 minute, the dimmer will automatically exit APM and return to Normal Operation.
• To save and exit immediately out of APM to Normal Operation, Press and Hold the Tap button until Indicator
Lights stop blinking.